ENGLEWOOD, CO ·
OSHA Inspection: FULL SERVICE BEVERAGE DBA 7UP BOTTLING GROUP OF CO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FULL SERVICE BEVERAGE DBA 7UP BOTTLING GROUP OF CO in 2840 SOUTH ZUNI ST., ENGLEWOOD, CO 80110 (NAICS 312111). OSHA activity number 307648857.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FULL SERVICE BEVERAGE DBA 7UP BOTTLING GROUP OF CO
- Site address
- 2840 SOUTH ZUNI ST.
- City
- ENGLEWOOD
- State
- CO
- ZIP
- 80110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 312111
- SIC code (legacy)
- 2086
- Employees
- 235
- Ownership type
- A
Citations
14 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 10, 2004
- Abate by
- Dec 13, 2004
- Penalty
- Initial $3,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential inhalation hazards of ammonia: 1. In the machine room, self-closing doors were not installed to the machine room (ANSI/ASHRAE 15-2001, Section 8.12.a). 2. Remote control of the mechanical equipment was not provided immediately outside the machine room, nor was a control switch provided for the ventilation in that room, (ANSI/ASHRAE 15-2001, Section 8.12.i). 3. Systems containing more than 110 lb (50kg) of refrigerant were not provided with durable signs having letters not less than 0.5 inches (12.7mm) in height designating the kind of refrigerant contained in exposed piping outside the machinery room (ANSI/ASHRAE 15-2001, Section 11.2.2). 4. The Machinery Room did not conform to Class 1, Division 2, of the National Electric Code when the employer provided neither continuously run mechanical ventilation systems that would actuate alarms upon failure of the ventilation system, nor detectors located in areas where refrigerant (ammonia) from leaks would concentrate, that would actuate alarms and mechanical ventilation systems at concentrations of 1000 ppm ammonia (ANSI/ASHRAE 15-2001, Section 8.12). 5. An alarm set at a value not greater than the OSHA PEL (50 ppm) and a detector for ammonia leaks were not provided in the machine room (ANSI/ASHRAE 15-2110, Section 8.11.2.1). 6. Signs reading "Authorized Personnel Only" were not posted on at the machine room (ANSI/ASHRAE 15-2001, Section 8.11.8). 7. Legible permanent signs indicating the name and address of the refrigerating system installer, number and amount of refrigerant, lubricant identity and amount, and field test pressure applied were not provided in the machine room (ANSI/ASHRAE 15-2001, Section 11.2). 8. Schematic drawings or panels giving directions for the operation and flow of the refrigeration system for emergency shutdown were not developed and available (ANSI/ASHRAE 15-2001, Section 11.7. 9. Emergency shutdown procedures were not developed or displayed in the machine room (ANSI/ASHRAE 15-2001, Section 11.7). Among other methods, one feasible and acceptable method to correct these hazards are: 1. Install self-closing doors to the Machinery room. 2. Ensure the mechanical equipment in the machinery room can be controlled via remote control. Ensure the control switches are located outside the machine room. 3. Ensure that all piping is labeled with the contents of the piping. 4. Ensure electrical devices are rated for Class 1 Division 2, or install a mechanical ventilation system that complies with ANSI/ASHRAE 15-2001. Provide continuously run mechanical ventilation system that would actuate alarms upon failure of the ventilation systems, or install detectors, located in areas where refrigerant from leaks would concentrate, that actuates alarms and mechanical ventilation at levels of 1000 ppm ammonia. 5. Install "Authorized Entry Only" signs to the entrance of the machine room. 6. Ensure pipe flow diagrams and/or schematics are developed and available, showing the direction of the flow of ammonia in the complete refrigeration system. 7. Install permanent signs indicating the name and address of the refrigerating system installer, number and amount of refrigerant, lubricant identity and amount, and field test pressure. 8. Develop emergency shut down procedures and ensure they are permanently placed in the machine room. Adhere to the safe design, installation, and operation of ammonia refrigeration systems as prescribed by the ANSI/ASHRAE 15-2001 (Safety Standard for Refrigeration Systems). Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
- · F (S)
- · Z (S) $3500.00
5(a)(1)
- Issued
- Nov 10, 2004
- Abate by
- Nov 16, 2004
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential inhalation hazards of ammonia: (a) Roof Area - Pressure relief devices did not discharge to the atmosphere at a location not less than 15 ft (4.57 m) above the adjoining ground level. The pressure relief devices were located approximately 6 inches above ground level and six inches near a drain located on the roof (ANSI/ASHRAE 15-2001, Section 9.7.8). Feasible and acceptable methods to correct these hazards, among others, include: (1) Discharge ammonia from pressure relief devices to the atmosphere at a location not less than 15 ft (4.57m) above the adjoining ground level, and eliminate the possibility of vapors entering the drain located on the roof. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- · F (S) $1750.00
- · Z (S) $3500.00
5(a)(1)
- Issued
- Nov 10, 2004
- Abate by
- Dec 13, 2004
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazards of defective equipment: (a) On or about October 5, 2004 and at times prior, employees were exposed to bodily injury while operating the Crown manually operated pallet jacks, which were in need of repair and had not been taken out of service. Among other methods, one feasible and acceptable method to correct these hazards are: 1. Ensure that the operators manual is followed by ensuring the pallet jacks are maintained in operating condition. Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
- · F (S) $1000.00
- · Z (S) $2000.00
1910.23 C01
- Issued
- Nov 10, 2004
- Abate by
- Nov 16, 2004
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- · F (S) $750.00
- · Z (S) $1500.00
1910.132 D02
- Issued
- Nov 10, 2004
- Abate by
- Dec 13, 2004
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- · F (S) $750.00
- · Z (S) $1500.00
1910.147 C06 I
- Issued
- Nov 10, 2004
- Abate by
- Dec 13, 2004
- Penalty
- Initial $2,500 · Current $1,250 Reduced
Recent events (2)
- · F (S) $1250.00
- · Z (S) $2500.00
1910.147 C07 I
- Issued
- Nov 10, 2004
- Abate by
- Dec 13, 2004
Recent events (2)
- · F (S)
- · Z (S)
1910.212 A01
- Issued
- Nov 10, 2004
- Abate by
- Nov 16, 2004
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- · F (S) $750.00
- · Z (S) $1500.00
1910.212 A03 II
- Issued
- Nov 10, 2004
- Abate by
- Nov 16, 2004
Recent events (2)
- · F (S)
- · Z (S)
1910.219 F03
- Issued
- Nov 10, 2004
- Abate by
- Nov 15, 2004
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- · F (S) $750.00
- · Z (S) $1500.00
1910.253 B04 III
- Issued
- Nov 10, 2004
- Abate by
- Nov 16, 2004
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- · F (S) $750.00
- · Z (S) $1500.00
1910.307 B
- Issued
- Nov 10, 2004
- Abate by
- Dec 13, 2004
- Penalty
- Initial $3,500 · Current $1,750 Reduced
Recent events (2)
- · F (S) $1750.00
- · Z (S) $3500.00
1910.303 G02 I
- Issued
- Nov 10, 2004
- Abate by
- Nov 16, 2004
Recent events (2)
- · F (O)
- · Z (O)
1910.305 G02 III
- Issued
- Nov 10, 2004
- Abate by
- Nov 15, 2004
Recent events (2)
- · F (O)
- · Z (O)
More inspections at Full Service Beverage DBA 7UP Bottling Group of CO
View Full Service Beverage DBA 7UP Bottling Group of CO's full OSHA safety record →
More inspections in this industry (NAICS 312111)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307648857.