AVENEL, NJ —
OSHA Inspection: ECOLAB, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of ECOLAB, INC. in 255 BLAIR ROAD, AVENEL, NJ 07001 (NAICS 000000). OSHA activity number 303280127.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ECOLAB, INC.
- Site address
- 255 BLAIR ROAD
- City
- AVENEL
- State
- NJ
- ZIP
- 07001
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2841
- Employees
- 120
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Sep 13, 2000
- Abate by
- Oct 10, 2000
- Penalty
- Initial $4,000 · Current $2,600 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to thermal and chemical burns and impact injuries caused by an eruption of liquid Towel Detergent and equipment disintegration: a- Production Building, Cast Process Area, Filler Lines A & B - On June 2, 2000 at about 7:30PM, Towel Detergent reacted violently within the fill system, propelling the hot liquid product and parts of the fill system device at the operator's station. Means were not provided to ensure that the detergent does not react within the system and that the operators are protected in the event of a reaction. Observed on June 13, 2000. Feasible methods, among others, to correct the condition is: 1- Ensure that system controllers such as the "Mag Meter" and "K-Tron" are in proper operating condition, and/or, install back-up controllers. a- Check for product chloride content on a frequent basis. b- Institute orderly shut down procedures in the event of excessive chloride content. c- Provide means to monitor and control the batch temperature. 2- Create a standard operating procedure for maintenance and preparation of the system which eliminates the presence of water. The procedure should be in writing, and employees, including operators and maintenance personnel, should be appropriately trained. The procedure is to include, but should not be limited to: a- Appropriate use of water pressure needed to adequately clean out the process system lines. b- Appropriate use of air at pressure and volume necessary to adequately dry out the process system lines and testing to assure that they are free of excess water. c- Contingency plans for appropriate cleaning in the event of abnormal operations such as a freeze up in the system has occurred. d- A checklist to ensure that appropriate cleaning has been conducted at all times. 3- Install a shield or door at the wall opening between the control panel and filler line system.
Recent events (2)
- — I (S) $2600.00
- — Z (S) $4000.00
More inspections at Ecolab, INC.
View Ecolab, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303280127.