ALBUQUERQUE, NM —
OSHA Inspection: PENSKE AUTO CENTER
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PENSKE AUTO CENTER in 2100 CARLISLE AVE NE, ALBUQUERQUE, NM 87110 (NAICS 000000). OSHA activity number 303403752.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PENSKE AUTO CENTER
- Site address
- 2100 CARLISLE AVE NE
- City
- ALBUQUERQUE
- State
- NM
- ZIP
- 87110
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 7538
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
90005 A
- Issued
- May 24, 2001
- Abate by
- Jun 20, 2001
- Penalty
- Initial $4,500 · Current $2,200 Reduced
General-duty citation text
THE CITATIONS ISSUED ON MAY 24, 2001, ARE HEREBY AMENDED TO READ: Section 50-9-5(A), NMSA 1978 (New Mexico Occupational Health and Safety Act): Every employer shall furnish to each of his employees employment and a place of employment which are free from recognized hazards that are causing or are likely to cause death or serious physical harm to his employees. The employer has not ensured that proper inspection and maintenance of the automotive lifts are being conducted. An inspection of the lifts in accordance; ANSI/ALI ALOIM Standard for Automotive Lifts, Safety and Health Requirements for Operation, Inspection and Maintenance, or an inspection in accordance with the company's own inspection procedures would have enabled the employer to identify and ensure maintenance on the following: 1) A broken pulley and components of the pulley system were observed laying on the floor under the lift. The lift cable was rigged with various hardware to control the slack resulting from the broken pulley system. The cables showed fraying as a result of the broken pulley. Locking pliers were used in place of a guide pin. 2)The electrical cord on lift #4 is showing wear on the insulation. There was a significant amount of hydraulic fluid leaking from the electrical hydraulic pump. Feasible Abatement: Development and implementation of an inspection and maintenance program in accordance with, ANSI/ALI ALOIM, Standard for Automotive Lifts, Safety Requirements for Operation, Inspection and Maintenance, to be used in conjunction with the company's existing program. Date Corrected Describe Corrective Action :
Recent events (2)
- — A (S) $2200.00
- — Z (S) $4500.00
1910.305 B01
- Issued
- May 24, 2001
- Abate by
- Jun 20, 2001
- Penalty
- Initial $1,800 · Current $500 Reduced
Recent events (2)
- — A (S) $500.00
- — Z (S) $1800.00
1910.305 B02
- Issued
- May 24, 2001
- Abate by
- Jun 20, 2001
Recent events (2)
- — A (S)
- — Z (S)
1910.157 C01
- Issued
- May 24, 2001
- Abate by
- Jun 13, 2001
1910.157 E03
- Issued
- May 24, 2001
- Abate by
- Jun 13, 2001
More inspections at Penske Auto Center
View Penske Auto Center's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NM
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303403752.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.