On , OSHA opened a follow-up safety inspection of ACE GREASE SERVICE, INC. in 9011 STATE ROUTE 163, MILLSTADT, IL 62260 (NAICS 423930). OSHA activity number 303821813.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACE GREASE SERVICE, INC.
- Site address
- 9011 STATE ROUTE 163
- City
- MILLSTADT
- State
- IL
- ZIP
- 62260
- Mailing
- 1517 EILER RD., BELLEVILLE, IL 62223
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- SIC code (legacy)
- 5093
- Employees
- 16
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 17, 2005
- Abate by
- Oct 4, 2005
- Penalty
- Initial $500 · Current $500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to suspended loads held by overhead hoists that were not periodically inspected: a)Shop area, Center of shop; Employees were exposed to the hazard of being struck by falling load, such as metal grease bins and brake drums, from an overhead electric hoist. The company did not have the 1 ton Yale underhung hoist inspected on a periodic basis (at least every twelve months) since it was installed approximately 2 years ago to determine wear, deterioration and malfunction as per ANSI B30.16-1. One method of abatement, among others, would be to have this electric hoist inspected on a periodic bases (at least every twelve months) as required by ANSI B30.16-1. **ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM**
1910.305 G01 III
- Issued
- Aug 17, 2005
- Abate by
- Oct 4, 2005
- Penalty
- Initial $500 · Current $500
1910.305 G02 III
- Issued
- Aug 17, 2005
- Abate by
- Oct 4, 2005
1910.305 B01
- Issued
- Aug 17, 2005
- Abate by
- Oct 4, 2005
- Penalty
- Initial $1,600 · Current $1,600
More inspections at ACE Grease Service, INC.
View ACE Grease Service, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303821813.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.