GAINESVILLE, FL ·
OSHA Inspection: SUMMIT ERECTORS, INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of SUMMIT ERECTORS, INC. in UNIVERSITY OF FLORIDA BEN HILL GRIFFIN STADIUM, GAINESVILLE, FL 32604 (NAICS 000000). OSHA activity number 303989701.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUMMIT ERECTORS, INC.
- Site address
- UNIVERSITY OF FLORIDA BEN HILL GRIFFIN STADIUM
- City
- GAINESVILLE
- State
- FL
- ZIP
- 32604
- Mailing
- 5470 HWY AVE, JACKSONVILLE, FL 32254
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (Y)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1791
- Employees
- 40
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 26, 2002
- Abate by
- Dec 3, 2002
- Penalty
- Initial $4,900 · Current $2,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to being struck by a falling brace: a.On or about July 24, 2002, the employer selected and installed Dayton Superior T-13 expansion anchor bolts which were not appropriate for use with the Meadow-Burke engineered brace system. This could cause the brace to separate from its anchor point on the concrete column, and fall onto an employee. b.On or about July 24, 2002, the employer did not use a torque wrench to install the Dayton Superior T-13 expansion anchor bolt onto the brace system. This could cause the brace to separate from its anchor point on the concrete column, and fall onto an employee. Among other methods, A feasible means of abatement would be: 1.Use an anchor bolt that is designed and recommended by the manufacturer of the brace. 2Use a torque wrench to apply and measure the amount of torque applied to the anchor bolt in accordance with the manufacturer's recommendation. ABATEMENT CERTIFICATION IS REQUIRED.TION
Recent events (2)
- · F (S) $2500.00
- · Z (S) $4900.00
1926.501 B12
- Issued
- Nov 26, 2002
- Abate by
- Dec 2, 2002
- Penalty
- Initial $4,900
Recent events (2)
- · F (S)
- · Z (S) $4900.00
1926.502 B04
- Issued
- Nov 26, 2002
- Abate by
- Dec 2, 2002
- Penalty
- Current $2,000
Recent events (2)
- · F (O) $2000.00
- · Z (S)
More inspections at Summit Erectors, INC.
View Summit Erectors, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 303989701.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.