Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: ACME ELECTRIC, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ACME ELECTRIC, INC. in 10 SOUTH GREEN VALLEY PARKWAY, HENDERSON, NV 89012 (NAICS 000000). OSHA activity number 304646490.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Acme Electric, INC. for free Get an email when a new federal OSHA severe-injury report for Acme Electric, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ACME ELECTRIC, INC.
Site address
10 SOUTH GREEN VALLEY PARKWAY
City
HENDERSON
State
NV
ZIP
89012
Mailing
4035 FLOSSMOOR, SUITE A, LAS VEGAS, NV 89115
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (Y)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
1794
Employees
3
Ownership type
Private (A)
Industry flags
Construction safety.

3 citations on file for this inspection.

618037501

Serious Gravity 03 1 instance 1 exposed
Issued
Oct 15, 2001
Abate by
Oct 18, 2001
Penalty
Initial $1,125 · Current $1,125
Nevada Revised Statute 618.375(1):  The employer did not furnish
employment and a place of
employment which was free from recognized hazards that were causing or
likely to cause death
or serious physical harm to employees:
The employer failed to ensure that a Fermec tractor loader's lifting
capacity was not exceeded
while lifting a concrete barrier rail:
a.A Fermec tractor, model #760, with backhoe and loader attachments was
utilized
at the job site, which was located on the west side of Green Valley
Parkway, just
South of the I-215.  The manufacturer's maximum suspended safe working load
in loader operations of 1000kg(2,200lbs), was significantly exceeded while
lifting
a concrete barrier, which weighted 5,850 lbs.  An employee's feet and legs
were
exposed to a crushing hazard while he guided the concrete barrier into
place.
REFERENCE: Fermec model 760 operator's manual,  page 28, which states "In
all instances, the maximum suspended safe working load in loader lifting
operations is 1,000kg, and page 112, which states "Loader Operation -
Warning -
Do not exceed the lifting capacity of the loader".
One feasible and acceptable method of abatement would be to ensure
operators
do not exceed the lifting capacity of the loader.

1926.21 B02

Serious Gravity 03 1 instance 1 exposed
Issued
Oct 15, 2001
Abate by
Oct 18, 2001
Penalty
Initial $1,125 · Current $1,125

1926.251 B01

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Oct 5, 2001
Abate by
Nov 5, 2001

View Acme Electric, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 304646490.