HENDERSON, NV ·
OSHA Inspection: ACME ELECTRIC, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ACME ELECTRIC, INC. in 10 SOUTH GREEN VALLEY PARKWAY, HENDERSON, NV 89012 (NAICS 000000). OSHA activity number 304646490.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACME ELECTRIC, INC.
- Site address
- 10 SOUTH GREEN VALLEY PARKWAY
- City
- HENDERSON
- State
- NV
- ZIP
- 89012
- Mailing
- 4035 FLOSSMOOR, SUITE A, LAS VEGAS, NV 89115
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (Y)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1794
- Employees
- 3
- Ownership type
- Private (A)
- Industry flags
- Construction safety.
Citations
3 citations on file for this inspection.
618037501
- Issued
- Oct 15, 2001
- Abate by
- Oct 18, 2001
- Penalty
- Initial $1,125 · Current $1,125
General-duty citation text
Nevada Revised Statute 618.375(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: The employer failed to ensure that a Fermec tractor loader's lifting capacity was not exceeded while lifting a concrete barrier rail: a.A Fermec tractor, model #760, with backhoe and loader attachments was utilized at the job site, which was located on the west side of Green Valley Parkway, just South of the I-215. The manufacturer's maximum suspended safe working load in loader operations of 1000kg(2,200lbs), was significantly exceeded while lifting a concrete barrier, which weighted 5,850 lbs. An employee's feet and legs were exposed to a crushing hazard while he guided the concrete barrier into place. REFERENCE: Fermec model 760 operator's manual, page 28, which states "In all instances, the maximum suspended safe working load in loader lifting operations is 1,000kg, and page 112, which states "Loader Operation - Warning - Do not exceed the lifting capacity of the loader". One feasible and acceptable method of abatement would be to ensure operators do not exceed the lifting capacity of the loader.
1926.21 B02
- Issued
- Oct 15, 2001
- Abate by
- Oct 18, 2001
- Penalty
- Initial $1,125 · Current $1,125
1926.251 B01
- Issued
- Oct 5, 2001
- Abate by
- Nov 5, 2001
More inspections at Acme Electric, INC.
View Acme Electric, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 304646490.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.