OSHA Inspection: G & S TECHNOLOGIES

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of G & S TECHNOLOGIES in 1800 HARRISON AVE., KEARNY, NJ 07032 (NAICS 000000). OSHA activity number 304674716.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G & S Technologies — free Get an email when a new federal OSHA severe-injury report for G & S Technologies is published. One employer, no account, unsubscribe in one click.
Establishment
G & S TECHNOLOGIES
Site address
1800 HARRISON AVE.
City
KEARNY
State
NJ
ZIP
07032
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
3612
Employees
98
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 1 exposed
Issued
Oct 10, 2001
Abate by
Oct 15, 2001
Penalty
Initial $1,600 · Current $800 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employmnent and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to:
a) Outside Yard near Incinerator:   Written "Safe Operating Procedures"
were not developed
by the employer for employee(s) engaged in cutting open the tops of pad
mounted
transformers with a cutting torch for the purpose of recovering copper.
Violation occurred on or about 8/1/01
AMONG OTHER METHODS ONE FEASIBLE AND ACCEPTABLE ABATEMENT
METHOD TO CORRECT THIS HAZARD IS TO:
1.   Develop and implement "Safe Operating Procedures" for cutting
operations
on
pad mounted transformers.
2.   Ensure all transformer bushings are kept open to allow sufficient air
to dilute the
gas concentration below the lower explosive limit.
3.   Ensure the use of a combustible gas meter to detect lower explosive
limit levels
in all pad mounted transformers prior to torch cutting operations.s
Recent events (2)
  • — I (S) $800.00
  • — Z (S) $1600.00

View G & S Technologies's full OSHA safety record →