OSHA Inspection: KANSAS CITY POWER & LIGHT LACYGNE GENERATOR

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KANSAS CITY POWER & LIGHT LACYGNE GENERATOR in 25166 E. 2200 RD., LACYGNE, KS 66040 (NAICS 000000). OSHA activity number 305032260.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kansas City Power & Light Lacygne Generator — free Get an email when a new federal OSHA severe-injury report for Kansas City Power & Light Lacygne Generator is published. One employer, no account, unsubscribe in one click.
Site address
25166 E. 2200 RD.
City
LACYGNE
State
KS
ZIP
66040
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
4911
Employees
258
Ownership type
A

1 citation on file for this inspection.

1910.269 V01 II

Serious Gravity 10 1 instance 5 exposed
Issued
Mar 3, 2003
Abate by
Mar 6, 2003
Penalty
Initial $4,500 · Current $4,500
Section 5(a)1 of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to fire, burns, and inhalation hazards:
On or about December 20, 2002, employee preforming a routine check of the
hot and cold air
dampers, located on the mezzanine level in unit 2, was exposed to fire and
explosion hazards
when an excess amount of heated air ruptured the blow out plate.  The
heated air, approximatley
600 degrees fahrenheit, was vented inside the building. Employees were
exposed to hazards
associated with fire, burns, and inhalation.
AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE METHOD TO
CORRECT THIS HAZARD IS:
Install hot air duct that will not 'blow out' when exposed to unusual or
extreme pressures, or
provide exterior venting for the hot air as referenced in ANSI B31.1 -
1977 American National
Standard Power Piping.
29 CFR 1903.19(c)(2) abatement of the above violation was verified at the
time of
inspection, no certification is required.tion
Recent events (2)
  • — F (S) $4500.00
  • — Z (S) $4500.00

View Kansas City Power & Light Lacygne Generator's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305032260.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.