Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: CENTRAL PRECISION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CENTRAL PRECISION, INC. in 20823 SAN MAR ROAD, BOONSBORO, MD 21713 (NAICS 000000). OSHA activity number 305125080.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Central Precision, INC. for free Get an email when a new federal OSHA severe-injury report for Central Precision, INC. is published. One employer, no account, unsubscribe in one click.
Site address
20823 SAN MAR ROAD
City
BOONSBORO
State
MD
ZIP
21713
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3444
Employees
48
Ownership type
A
Industry flags
Manufacturing safety.

20 citations on file for this inspection.

50104 A

Serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Nov 3, 2002
Penalty
Initial $1,800 · Current $500 Reduced
Labor and Employment Article, Section 5-104(a): The employer did not
furnish employment
and a place of employment which were free from recognized hazards that
were causing or
likely to cause death or serious physical harm to employees:
(a)Date of Violation:09/05/02
Condition:Employees could be struck by ruptured plastic piping, 3/4" to 1
1/2"
diameter Schedule 40 PVC piping and fittings installed from the air
compressor through the entire shop area, used to distribute compressed
air at 92 p.s.i.
Among other methods, one feasible and acceptable abatement method to
correct the hazard is
to replace the PVC pipe with a proper compressed air piping system
approved
for this
purpose.
Abatement documentation (photographs, receipts, copies of programs,
training
certification, etc.) is required for this item.
Recent events (2)
  • · I (S) $500.00
  • · Z (S) $1800.00

1910.107 B09

Serious 1 instance 2 exposed
Issued
Oct 29, 2002
Abate by
Nov 1, 2002
Penalty
Initial $562 · Current $100 Reduced
Recent events (2)
  • · I (S) $100.00
  • · Z (S) $562.00

1910.107 E02

Serious 1 instance 2 exposed
Issued
Oct 29, 2002
Abate by
Nov 1, 2002

1910.132 F01 I

Serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Dec 1, 2002
Penalty
Initial $1,350 · Current $100 Reduced
Recent events (2)
  • · I (S) $100.00
  • · Z (S) $1350.00

1910.138 A

Serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Nov 3, 2002

1910.147 C04 I

Serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Dec 1, 2002
Penalty
Initial $1,575 · Current $1,000 Reduced
Recent events (2)
  • · I (S) $1000.00
  • · Z (S) $1575.00

1910.147 C06 IA

Serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Dec 1, 2002

1910.147 C07 I

Serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Dec 1, 2002

1910.178 L01 I

Serious 1 instance 10 exposed
Issued
Oct 29, 2002
Abate by
Dec 1, 2002
Penalty
Initial $1,800 · Current $500 Reduced
Recent events (2)
  • · I (S) $500.00
  • · Z (S) $1800.00

1910.212 A03 II

Serious 4 instances 8 exposed
Issued
Oct 29, 2002
Abate by
Nov 3, 2002
Penalty
Initial $1,575 · Current $250 Reduced
Recent events (2)
  • · I (S) $250.00
  • · Z (S) $1575.00

1910.1200 E01

Serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Nov 1, 2002
Penalty
Initial $1,575 · Current $250 Reduced
Recent events (2)
  • · I (S) $250.00
  • · Z (S) $1575.00

1910.1200 H01

Serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Dec 1, 2002

50405 B01

Serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Nov 3, 2002

50406 A01

Serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Nov 16, 2002

1910.132 D02

Other-than-serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Nov 3, 2002

1910.132 F04

Other-than-serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Dec 1, 2002

1910.147 C06 II

Other-than-serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Dec 1, 2002

1910.147 C07 IV

Other-than-serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Dec 1, 2002

1910.178 L06

Other-than-serious 1 instance 3 exposed
Issued
Oct 29, 2002
Abate by
Dec 1, 2002

1910.303 F

Other-than-serious 1 instance 48 exposed
Issued
Oct 29, 2002
Abate by
Nov 3, 2002

View Central Precision, INC.'s full OSHA safety record →