SOUTH HOLLAND, IL ·
OSHA Inspection: BROWN PACKING COMPANY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BROWN PACKING COMPANY, INC. in 1 DUTCH VALLEY DR., SOUTH HOLLAND, IL 60473 (NAICS 311611). OSHA activity number 305998262.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BROWN PACKING COMPANY, INC.
- Site address
- 1 DUTCH VALLEY DR.
- City
- SOUTH HOLLAND
- State
- IL
- ZIP
- 60473
- Mailing
- P.O. BOX 703, SOUTH HOLLAND, IL 60473
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (Y)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311611
- SIC code (legacy)
- 2011
- Employees
- 68
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Oct 9, 2003
- Abate by
- Nov 11, 2003
- Penalty
- Initial $875 · Current $613 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were likely to cause death or serious physical harm to employees in that employees were exposed to: Engine room: On or about June 25, 2003, the engine room presented the following hazards to employees: 1. It contained a gas-fired water heater with an open flame that used combustion air from within the engine room. 2. The mechanical equipment in the engine room was not provided with a remote control located immediately outside the machinery room door solely for the purpose of shutting down the equipment in case of an emergency. 3. The ventilation fans for the engine room did not have a control switch located immediately outside the engine room door. 4. A door communicating with the engine room was not tight fitting and self-closing. 5. Emergency shut-down procedures, including precautions to be taken in case of a breakdown or leak, were not posted posted outside the engine room immediately adjacent to each door. Feasible methods of abatement include, but are not limited to, complying with ANSI/ASHRAE Safety Code for Mechanical Refrigeration (15-2001).
Recent events (2)
- · I (S) $612.50
- · Z (S) $875.00
More inspections at Brown Packing Company, INC.
View Brown Packing Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311611)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 305998262.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.