OSHA Inspection: HOVENSA LLC

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of HOVENSA LLC in HOVENSA REFINERY,1 ESTATE HOPE, ST CROIX, VI 00820 (NAICS 324110). OSHA activity number 306195199.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hovensa LLC — free Get an email when a new federal OSHA severe-injury report for Hovensa LLC is published. One employer, no account, unsubscribe in one click.
Establishment
HOVENSA LLC
Site address
HOVENSA REFINERY,1 ESTATE HOPE
City
ST CROIX
State
VI
ZIP
00820
Mailing
1 ESTATE HOPE, CHRISTIANSTED, ST CROIX, VI 00820
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
324110
SIC code (legacy)
2911
Employees
2500
Ownership type
A
Industry flags
Manufacturing safety.

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 24, 2009
Abate by
Jan 13, 2010
Penalty
Initial $5,000 · Current $5,000
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to burns:
a.Unit #2 - Waste Heat Boiler (WHB) Platform: On or about 6/4/09,
employees were
exposed to being burned by hot water and condensate while draining water
from the
WHB Steam Drum through the blow down piping system located at the top of
the unit
#2 platform, while a sight level glass installation was taking place, due
to the location
of the blow down exhaust.
ABATEMENT NOTES:
Among other methods, one feasible method of abatement to reduce this
hazard is to:
1.Follow the recommendation of the National Board Inspection Code 2007,
Part 1
Installation, Section 2.7.5 (l) which states that "The discharge of
blowoff pipes shall be
located so as to prevent injury to personnel".
Note: In addition to abatement certification, the employer is required to
submit
abatement documentation for this item in accordance with 29 CFR 1903.19(c)
and
(d), respectively.
Recent events (2)
  • — F (S) $5000.00
  • — Z (S) $5000.00

1910.147 C04 I

Serious Gravity 10 1 instance 6 exposed
Issued
Nov 24, 2009
Abate by
Jan 13, 2010
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and
utilized for the
control of potentially hazardous energy when employees were engaged in
activities covered by
this section:
a.Unit #2 - Waste Heat Boiler (WHB) Platform: On or about 6/4/09, the
employer did not
develop, document and utilize LOTO procedures to isolate the WHB Blow Down
Drum
from hazardous energy sources (upstream boiler).
NOTE:Certification and documentation of abatement must be submitted for
this
citation item as required by 29 CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — F (S) $5000.00
  • — Z (S) $5000.00

1910.147 C04 IIB

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Nov 24, 2009
Abate by
Jan 13, 2010
29 CFR 1910.147(c)(4)(ii) (B): The energy control procedures did not
clearly and specifically
outline the steps for shutting down, isolating, blocking and securing
machines or equipment to
control hazardous energy:
a.Unit #2 - Waste Heat Boiler (WHB) Platform:  On or about 6/4/09, the
employer's
LOTO procedures failed to outline the steps utilized for the control of
potentially
hazardous energy including, but not limited to:
a) means of isolating WHB Blow Down Drum from hazardous energy
sources (upstream boiler).
b) means of draining the WHB Steam Drum.
c) means of relieving stored energy.
d) means of preventing re-accumulation of hot water and condensate in the
WHB Blow Down Drum.
NOTE:Certification and documentation of abatement must be submitted for
this
citation item as required by 29 CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — F (S)
  • — Z (S)

1910.147 C07 I

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Nov 24, 2009
Abate by
Jan 13, 2010
Penalty
Initial $5,000
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure
that employees
acquired the knowledge and skills required for the safe application, usage
and removal of energy
control devices:
a.Unit #2- Waste Heat Boiler (WBH) Platform:  On or about 6/4/09,
employees who were
draining the WHB Steam Drum were not trained on how to lock it out.
NOTE:Certification and documentation of abatement must be submitted for
this
citation item as required by 29 CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — F (S)
  • — Z (S) $5000.00

View Hovensa LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306195199.