TWIN FALLS, ID —
OSHA Inspection: KIDD CONSTRUCTION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of KIDD CONSTRUCTION in LOCUST AND LAWNDALE, TWIN FALLS, ID 83301 (NAICS 236115). OSHA activity number 306438219.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KIDD CONSTRUCTION
- Site address
- LOCUST AND LAWNDALE
- City
- TWIN FALLS
- State
- ID
- ZIP
- 83301
- Mailing
- 520 EAST MAIN, JEROME, ID 83338
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- SIC code (legacy)
- 1521
- Employees
- 4
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 30, 2004
- Abate by
- May 12, 2004
- Penalty
- Initial $750 · Current $750
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of trusses collapsing from being inadequately braced: (a) Residential Construction Site at Locust and Lawndale, Twin Falls, ID: Southwest end: Employee(s) used a single 2" x 6" brace instead of building exterior ground bracing to support the first truss. Note: Abatement certification required for this item. Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow the guidelines for temporary bracing set forth in BCSI-B1/B2 summary sheet - Truss Installation and Temporary Bracing published by the Wood Truss Council of America
1926.501 B13
- Issued
- Apr 30, 2004
- Abate by
- May 12, 2004
1926.404 F06
- Issued
- Apr 30, 2004
- Abate by
- May 12, 2004
1926.403 B02
- Issued
- Apr 30, 2004
- Abate by
- May 12, 2004
More inspections at Kidd Construction
View Kidd Construction's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306438219.