Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: TESTA CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TESTA CORPORATION in CHARLESTOWN NAVY YARD, CHARLESTOWN, MA 02129 (NAICS 238910). OSHA activity number 306811381.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Testa Corporation for free Get an email when a new federal OSHA severe-injury report for Testa Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
TESTA CORPORATION
Site address
CHARLESTOWN NAVY YARD
City
CHARLESTOWN
State
MA
ZIP
02129
Mailing
50 SALEM STREET, LYNNFIELD, MA 01940
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (Y)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
SIC code (legacy)
1795
Employees
120
Ownership type
Private (A)

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 5 exposed
Issued
Jun 24, 2004
Abate by
Jul 2, 2004
Penalty
Initial $4,000 · Current $2,800 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazards associated with:  The flame cutting of
unsupported I-beams.
Location:  The Charlestown Navy shipyard.
1.  The employee was seriously injured when a section of the I-beam that
he was
flame cutting fell over on to the employee breaking his leg and pinning
him to the
ground.
Among other methods, One feasible and acceptable abatement method would be
to brace the sections of the I-beams being cut to prevent them from
falling over.ng