MUNDELEIN, IL —
OSHA Inspection: LARSEN MANUFACTURING, L.L.C.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LARSEN MANUFACTURING, L.L.C. in 906 EAST HIGH STREET, MUNDELEIN, IL 60060 (NAICS 332116). OSHA activity number 306931411.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LARSEN MANUFACTURING, L.L.C.
- Site address
- 906 EAST HIGH STREET
- City
- MUNDELEIN
- State
- IL
- ZIP
- 60060
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 332116
- SIC code (legacy)
- 3469
- Employees
- 22
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 10, 2003
- Abate by
- Oct 14, 2003
- Penalty
- Initial $375 · Current $263 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of contact with a moving saw blade: a) In the machine shop the Do-All horizontal band saw with serial number 5215804 was not equipped with a magnetic re-starter or similar device, as prescribed by the American National Standards for Metal Cutting Saws, ANSI B11.10-1990, Section 5.2.3.4, that in the event of an interruption in the electrical supply would prevent the saw from restarting automatically when power is restored. b) In the machine shop the Enco vertical band saw with serial number 921396 was not equipped with a magnetic re-starter or similar device, as prescribed by the American National Standards for Metal Cutting Saws, ANSI B11.10-1990, Section 5.2.3.4, that in the event of an interruption in the electrical supply would prevent the saw from restarting automatically when power is restored. A feasible means of abatement would be to provide a magnetic re-starter or similar device as required by ANSI B11-10.1990. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).s
Recent events (2)
- — I (S) $262.50
- — Z (S) $375.00
1910.147 C04 I
- Issued
- Sep 10, 2003
- Abate by
- Oct 14, 2003
- Penalty
- Initial $375 · Current $263 Reduced
Recent events (2)
- — I (S) $262.50
- — Z (S) $375.00
1910.147 C06 IA
- Issued
- Sep 10, 2003
- Abate by
- Oct 14, 2003
Recent events (2)
- — I (S)
- — Z (S)
1910.147 C07 I
- Issued
- Sep 10, 2003
- Abate by
- Oct 14, 2003
Recent events (2)
- — I (S)
- — Z (S)
1910.217 E01 I
- Issued
- Sep 10, 2003
- Abate by
- Sep 22, 2003
- Penalty
- Initial $375 · Current $263 Reduced
Recent events (2)
- — I (S) $262.50
- — Z (S) $375.00
More inspections at Larsen Manufacturing, L.L.C.