Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: O'HARA CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of O'HARA CORPORATION in F/T DEFENDER, DUTCH HARBOR, AK 99692 (NAICS 311712). OSHA activity number 307504134.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch O'Hara Corporation for free Get an email when a new federal OSHA severe-injury report for O'Hara Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
O'HARA CORPORATION
Site address
F/T DEFENDER
City
DUTCH HARBOR
State
AK
ZIP
99692
Mailing
120 TILLSON AVENUE, ROCKLAND, ME 04841
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311712
SIC code (legacy)
2092
Employees
27
Ownership type
Private (A)

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 4 instances 3 exposed
Issued
Feb 18, 2009
Abate by
Feb 24, 2009
Penalty
Initial $5,000 · Current $3,750 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that
employees were
exposed to electrical hazards in the engine room:
(a)O'Hara Corporation (F/T Defender) Engine Room and Galley: On or about
January 30,
2009, unqualified employees were exposed to electrical shock hazards due
to several
unguarded openings exposing energized busbars and inadequate labeling on
four of the
220V 100 amp panels serving the galley and engineroom.
Among other methods, a feasible means of abatement would include
protecting open circuits
with a cover as required by the 2008 NEC article 110.27(A)(2) and legibly
labeling disconnects
within panels as required by the 2008 NEC 110.22(A).
Recent events (2)
  • · I (S) $3750.00
  • · Z (S) $5000.00

1918.91 A

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Feb 18, 2009
Abate by
Mar 23, 2009

View O'Hara Corporation's full OSHA safety record →