CRAIG, CO —
OSHA Inspection: BOELENS' WELL SERVICE
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of BOELENS' WELL SERVICE in PILGRIM 1-10SW SW, SEC. 10-T10N, R93W, CRAIG, CO 81625 (NAICS 213112). OSHA activity number 307524579.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOELENS' WELL SERVICE
- Site address
- PILGRIM 1-10SW SW, SEC. 10-T10N, R93W
- City
- CRAIG
- State
- CO
- ZIP
- 81625
- Mailing
- P.O. BOX 352, THERMOPOLIS, WY 82443
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- SIC code (legacy)
- 1389
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 14, 2004
- Abate by
- Dec 27, 2004
- Penalty
- Initial $875 · Current $875
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of falling: a) Boelens' Well Service, Pilgrim 1-10 SW SW, Sec. 10 T10N, R93W, Craig, CO: An employee standing on the derrick monkeyboard was not equipped with above the rig floor or other working surfaces, shall be protected at all times from falling by guardrails systems, safety net systems, or personal fall arrest systems (PFAS). When PFAS are utilized the following shall apply. a) Personnel shall use a full body harness manufactured in accordance with ANSI Z359.1. b) PFAS shall be inspected prior to each use. c) The full body harness shall be attached by means of a lanyard with double-locking snap- hooks and, an anchor or structural member capable of supporting a minimum dead weight of 5,400 pounds. d) A separate lanyard shall be used by each person requiring a lanyard. The lanyard shall be adjusted to permit a maximum drop of five (5) feet in case of a fall. e) Manufacture's instructions for inspection and replacement should be followed.
1910.23 C01
- Issued
- Dec 14, 2004
- Abate by
- Dec 22, 2004
- Penalty
- Initial $700 · Current $700
1910.141 C01 I
- Issued
- Dec 14, 2004
- Abate by
- Dec 22, 2004
More inspections at Boelens' Well Service