COLORADO SPRINGS, CO —
OSHA Inspection: TRANEX, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRANEX, INC. in 2350 EXECUTIVE CIR., COLORADO SPRINGS, CO 80906 (NAICS 334416). OSHA activity number 307648881.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRANEX, INC.
- Site address
- 2350 EXECUTIVE CIR.
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80906
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334416
- SIC code (legacy)
- 3677
- Employees
- 55
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 22, 2004
- Abate by
- Aug 24, 2004
- Penalty
- Initial $525
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the possibility of dropped loads resulting in crushing hazards: (a) On or about July 20, 2004 and at times prior, employees were exposed to potential crushing injury from loss of load, while using the Lodestar, 1 ton hoist located in production area, which was not inspected to ensure the critical components were in good operational order. ABATEMENT NOTE: Among other methods, one feasible acceptable abatement method to correct his hazard is to: (a) Perform frequent inspections at daily to monthly intervals as per ANSI B-30- 16-1.2.1.2 and 2.2.1.2 on items such as: 1.All controls and operating mechanisms for improper operation; daily. 2.All safety devices for malfunction; daily. 3.Deterioration or leakage in air systems, if applicable. 4.Hooks for deformations, chemical damage, or cracks.Other load-bearing components of the hoist; daily. 5.Load-carrying ropes.Visual inspection daily for wear, twist, distortion or improper dead-ending to the hoisting drum and other attachments. Check chain also for deposits of foreign material which may be carried into the hoist mechanism. (b) Perform periodic inspections at monthly to yearly intervals as per ANSI B30.16 2.2.1.3, which includes the requirements specified above plus: 1.Loose bolts or rivets. 2.Cracked or worn drums or sheaves. 3.Worn, corroded, cracked or distorted parts such as pins, bearings, shafts, gears, rollers, locking and clamping devices. 4.Excessive wear on motor or load brake. 5.Excessive wear of chain, rope, load sprockets, drums, sheaves, and chain stretch. 6 Hooks. Dye penetrants, magnetic particle or other suitable crack detecting inspections should be performed at least once per year. 7.Electrical apparatus for signs of pitting or any deterioration of controller contractors, limit switches and push button stations. 8.Hook retaining nuts or collars and pins, welds or riveting used to secure the retaining members should be inspected. 9.Supporting structure and trolley if used shall be inspected, for continued ability to support the imposed loads. 10.Warning label for absence or illegibility. (c) Written, dated and signed inspection reports and records should be made monthlyon critical items such as brakes, hooks, chains and ropes. Records should be readily available. Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
- — I (S)
- — Z (S) $525.00
1910.132 D02
- Issued
- Jul 22, 2004
- Abate by
- Aug 24, 2004
Recent events (2)
- — I (O)
- — Z (O)
1910.147 C01
- Issued
- Jul 22, 2004
- Abate by
- Aug 24, 2004
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Tranex, INC.
View Tranex, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334416)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307648881.