GREENVILLE, NC —
OSHA Inspection: DEERFIELD CONSTRUCTION COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DEERFIELD CONSTRUCTION COMPANY, INC. in 520 SE GREENVILLE BLVD., GREENVILLE, NC 27834 (NAICS 236220). OSHA activity number 307905679.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DEERFIELD CONSTRUCTION COMPANY, INC.
- Site address
- 520 SE GREENVILLE BLVD.
- City
- GREENVILLE
- State
- NC
- ZIP
- 27834
- Mailing
- 8960 GLENDALE MILFORD RD., LOVELAND, OH 45140
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- SIC code (legacy)
- 1542
- Employees
- 59
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
1 citation on file for this inspection.
95012901
- Issued
- Oct 14, 2004
- Abate by
- Nov 9, 2004
- Penalty
- Initial $175 · Current $175
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to contact with electricity which could result in electrocution: Conductors were not spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. All splices and joints and free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose [NEC 110-14(b)]; Direct buried conductors and cables emerging from the ground were not protected by enclosures or raceways extending from the minimum cover distance required by Section 300-5(a) below grade to a point at least 8 ft. above finished grade. Where the enclosure or raceway is subject to physical damage, the conductors were not installed in rigid metal conduit, intermediate metal conduit, Schedule 80 rigid non metallic conduit, or equivalent [NEC 300-5(d)]; 200 ft., Type NM-B, 10-3 wire cord was use as service-entrance cable [336-5(a)(2)]: a)Southeast corner of building, base of scaffold, near down spout clean out - 200 ft., 110 volt, 40 amp, Type NM-B, 10-3 wire cord, partially buried underground, supplying power to temporary power panel in building, from main power pole near job trailer, 200 feet away, was being used as service-entrance cable, and spliced with wire nuts and black electrician tape. One feasible and acceptable method of abatement, among others, to correct this hazard is to replace this Type NM-B, 10-3 cord, being used as a service-entrance cable, with a Type SE or USE cable, and protect it from damage by enclosing it in some type of rigid conduit.
More inspections at Deerfield Construction Company, INC.
View Deerfield Construction Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307905679.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.