OSHA Inspection: DE LA GARZA FENCE COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DE LA GARZA FENCE COMPANY in 6475 W OLD US HIGHWAY 90, SAN ANTONIO, TX 78227 (NAICS 332618). OSHA activity number 307950675.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DE LA Garza Fence Company for free Get an email when a new federal OSHA severe-injury report for DE LA Garza Fence Company is published. One employer, no account, unsubscribe in one click.
Site address
6475 W OLD US HIGHWAY 90
City
SAN ANTONIO
State
TX
ZIP
78227
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
SIC code (legacy)
3496
Employees
21
Ownership type
Private (A)
Industry flags
Manufacturing safety.

12 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 10 exposed
Issued
Feb 7, 2005
Abate by
Feb 11, 2005
Penalty
Initial $1,000 · Current $1,000
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazards of potential explosion while using job made
heaters:
a)  At the site, in the covered welding area, employees were using job
made heaters.
These heaters operate using natural gas.  The gas supply lines, from the
gas cut off to the
heater, consisted of rubber tubes.  These tubes are not U.L. approved for
use as a natural gas
supply line, thus exposing employee to the potential natural gas leaks and
possible explosion.
Also the job made heaters had no regulators installed or other means to
control the gas/ air
mixture, thus potentially exposing employee to carbon monoxide.  The
heater enclosure, a 55
gallon metal drum, exposed the employees to burns due to the proximity to
the aisle.
Among other methods, one feasible and acceptable abatement method to
correct the
hazard would be to purchase heaters and installation hardware approved by
a nationally
recognized testing laboratory.

1910.106 B02 VIIA

Serious Gravity 01 1 instance 12 exposed
Issued
Feb 7, 2005
Abate by
Feb 11, 2005
Penalty
Initial $750 · Current $200 Reduced
Recent events (2)
  • · I (S) $200.00
  • · Z (S) $750.00

1910.106 B02 VIIC3

Serious Gravity 01 1 instance 12 exposed
Issued
Feb 7, 2005
Abate by
Feb 11, 2005

1910.178 A03

Serious Gravity 01 1 instance 1 exposed
Issued
Feb 7, 2005
Abate by
Feb 11, 2005
Penalty
Initial $750 · Current $200 Reduced
Recent events (2)
  • · I (S) $200.00
  • · Z (S) $750.00

1910.178 A06

Serious Gravity 01 1 instance 1 exposed
Issued
Feb 7, 2005
Abate by
Feb 11, 2005

1910.178 L01 I

Serious Gravity 01 2 instances 2 exposed
Issued
Feb 7, 2005
Abate by
Feb 11, 2005
Penalty
Initial $750 · Current $200 Reduced
Recent events (2)
  • · I (S) $200.00
  • · Z (S) $750.00

1910.178 Q07

Serious Gravity 01 1 instance 1 exposed
Issued
Feb 7, 2005
Abate by
Feb 11, 2005
Penalty
Initial $750 · Current $200 Reduced
Recent events (2)
  • · I (S) $200.00
  • · Z (S) $750.00

1910.212 A01

Serious Gravity 01 1 instance 1 exposed
Issued
Feb 7, 2005
Abate by
Feb 11, 2005
Penalty
Initial $750 · Current $200 Reduced
Recent events (2)
  • · I (S) $200.00
  • · Z (S) $750.00

1910.252 B02 III

Serious Gravity 02 1 instance 10 exposed
Issued
Feb 7, 2005
Abate by
Feb 11, 2005
Penalty
Initial $1,000 · Current $500 Reduced
Recent events (2)
  • · I (S) $500.00
  • · Z (S) $1000.00

1910.305 A01 I

Serious Gravity 01 1 instance 1 exposed
Issued
Feb 7, 2005
Abate by
Feb 11, 2005
Penalty
Initial $750 · Current $200 Reduced
Recent events (2)
  • · I (S) $200.00
  • · Z (S) $750.00

1910.22 B02

Other-than-serious Gravity 01 1 instance 10 exposed
Issued
Feb 7, 2005
Abate by
Feb 11, 2005

1910.157 C01

Other-than-serious Gravity 01 1 instance 12 exposed
Issued
Feb 7, 2005
Abate by
Feb 11, 2005

View DE LA Garza Fence Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 307950675.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.