OSHA Inspection: DE LA GARZA FENCE COMPANY

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of DE LA GARZA FENCE COMPANY in 6475 W OLD US HIGHWAY 90, SAN ANTONIO, TX 78227 (NAICS 332618). OSHA activity number 339500159.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DE LA Garza Fence Company for free Get an email when a new federal OSHA severe-injury report for DE LA Garza Fence Company is published. One employer, no account, unsubscribe in one click.
Site address
6475 W OLD US HIGHWAY 90
City
SAN ANTONIO
State
TX
ZIP
78227
Mailing
6475 W OLD US HIGHWAY 90, SAN ANTONIO, TX 78227
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
Employees
26
Ownership type
Private (A)

5 citations on file for this inspection.

1910.219 C02 I

Serious Gravity 10 3 instances 5 exposed
Issued
Mar 11, 2014
Abate by
Apr 3, 2014
Penalty
Initial $4,900 · Current $4,900
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:        a)  On or about November 26, 2013, and at times prior thereto employees exposed to a caught-in hazard when rotating shafts in the operators area on the Bergandi 2MT chain link fence weaver machine number three of five in the main production area were not adequately guarded.        b) On or about November 26, 2013, and at times prior thereto employees exposed to a caught-in hazard when rotating shafts in the operators area on the Bergandi 2MT chain link fence weaver machine number four of five in the main production area were not adequately guarded.        c) On or about November 26, 2013, and at times prior thereto employees exposed to a caught-in hazard when rotating shafts in the operators area on the Bergandi 2MT chain link fence weaver machine number five of five in the main production area were not adequately guarded.
Recent events (2)
  • · I (S) $4900
  • · Z (S) $4900

1910.219 F03

Serious Gravity 10 3 instances 5 exposed
Issued
Mar 11, 2014
Abate by
Apr 3, 2014
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:       a)  On or about November 26, 2013, and at times prior thereto employees exposed to a caught-in hazard when gears and sprockets on the second in line Bergandi 2MT chain link fence weaver machine from the office near the rear of the main production area were not adequately guarded.           b)  On or about November 26, 2013, and at times prior thereto employees exposed to a caught-in hazard when gears and sprockets on the thrid in line Bergandi 2MT chain link fence weaver machine from the office near the rear of the main production area were not adequately guarded.        c) On or about November 26, 2013, and at times prior thereto employees exposed to a caught-in hazard when gears and sprockets on the fourth in line Bergandi 2MT chain link fence weaver machine from the office near the rear of the main production area were not adequately guarded.        d) On or about November 26, 2013, and at times prior thereto employees exposed to a caught-in hazard when gears and sprockets on the fifth in line Bergandi 2MT chain link fence weaver machine from the office near the rear of the main production area were not adequately guarded.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4900

1910.303 G02 I

Serious Gravity 10 4 instances 5 exposed
Issued
Mar 11, 2014
Abate by
Mar 29, 2014
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):        a)  On or about November 26, 2013, and at times prior thereto employees exposed to an electrical shock hazard when the control box on the second Bergandi 2MT chain link fence weaver machine in line from the office was not adequately covered, exposing employees to an electrical shock hazard of 120 volts.        b) On or about November 26, 2013, and at times prior thereto employees exposed to an electrical shock hazard when the control box on the third Bergandi 2MT chain link fence weaver machine in line from the office was not adequately covered, exposing employees to an electrical shock hazard of 120 volts.        c) On or about November 26, 2013, and at times prior thereto employees exposed to an electrical shock hazard when the control box on the fourth Bergandi 2MT chain link fence weaver machine in line from the office was not adequately covered, exposing employees to an electrical shock hazard of 120 volts.        d) On or about November 26, 2013, and at times prior thereto employees exposed to an electrical shock hazard when the control box on the fifth Bergandi 2MT chain link fence weaver machine in line from the office was not adequately covered, exposing employees to an electrical shock hazard of 120 volts.
Recent events (2)
  • · I (S) $2940
  • · Z (S) $4900

1910.305 B01 I

Serious Gravity 5 2 instances 5 exposed
Issued
Mar 11, 2014
Abate by
Mar 24, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:        a)  On or about November 26, 2013, and at times prior thereto employees exposed to an electrical shock hazard when control box openings on the third Bergandi 2MT chain link fence weaver machine were not adequately closed, exposing employees to an electrical shock hazard of 120 volts.        b) On or about November 26, 2013, and at times prior thereto employees exposed to an electrical shock hazard when control box openings on the fifth Bergandi 2MT chain link fence weaver machine were not adequately closed, exposing employees to an electrical shock hazard of 120 volts.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $3500

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 11, 2014
Abate by
Mar 29, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:        On or about November 26, 2013, and at times prior thereto employees exposed to an electrical shock hazard when an electrical cord on the third Bergandi 2MT chain link fence weaver machine showed obvious strain-relief damage, exposing employees to an electrical shock hazard of 120 volts.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

View DE LA Garza Fence Company's full OSHA safety record →