OSHA Inspection: PRO BUILDERS

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of PRO BUILDERS in 109 WEST PINE, CASCADE, ID 83611 (NAICS 238130). OSHA activity number 308341999.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PRO Builders — free Get an email when a new federal OSHA severe-injury report for PRO Builders is published. One employer, no account, unsubscribe in one click.
Establishment
PRO BUILDERS
Site address
109 WEST PINE
City
CASCADE
State
ID
ZIP
83611
Mailing
2315 SUNSET AVENUE, BOISE, ID 83702
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
SIC code (legacy)
1751
Employees
8
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 8 exposed
Issued
Nov 7, 2005
Abate by
Nov 10, 2005
Penalty
Initial $2,000 · Current $1,000 Reduced
Section 5(a)(1) of the Occupational Safety & Health Act of 1970:The
employer did not furnish employment
and a place of employment which were free from recognized hazards that
were causing or likely to cause
death or serious physical harm to employees in that employees were exposed
to structural collapse:
a)South exterior wall of the Sanctuary - Cascade Community Church - 109
West Pine, Cascade, ID; On
or about 10/26/05 and at times prior thereto, the employer did not ensure
that a load-bearing exterior
wall was adequately constructed and laterally supported prior to placing
roof trusses onto the wall,
thereby exposing employees working on/around/under the wall and/or trusses
to the hazard of being
struck by the collapsing structure.
Note: Among other methods, one feasible and acceptable abatement method to
correct this hazard would be
following the temporary bracing requirements for roof truss installation
per the Truss Manufacturer and/or
Wood Truss Council of America's "Building Component Safety Information"
Bulletin BCSI 1-03.
b)Sanctuary area - Cascade Community Church - 109 West Pine, Cascade, ID;
On or about 10/26/05
and at times prior thereto, the employer did not ensure that roof trusses
were laterally supported with
diagonal bracing as they were installed, thereby exposing employees
working on/around/under the wall
and/or trusses to the hazard of being struck by the collapsing structure.
Note:  Among other methods, one feasable and acceptable abatement method
to correct this hazard would be
following the temporary bracing requirements for roof truss installation
per the Truss Manufacturer and/or
Wood Truss Council of America's "Building Component Safety Information"
Bulletin BCSI 1-03.
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $2000.00

5(a)(1)

Serious Gravity 10 1 instance 8 exposed
Issued
Nov 7, 2005
Abate by
Nov 10, 2005
Section 5(a)(1) of the Occupational Safety & Health Act of 1970:The
employer did not furnish employment
and a place of employment which were free from recognized hazards that
were causing or likely to cause
death or serious physical harm to employees in that employees were exposed
to roof truss explosion and/or
collapse:
a)South side staging area and Sanctuary area - Cascade Community Church -
109 West Pine, Cascade,
ID; On or about 10/26/05 and at times prior thereto, the employer did not
ensure that a spreader bar
or "stiffback" was utilized for hoisting/placing roof trusses with a span
greater than 30 feet, thereby
exposing employees working on/around/under the trusses and/or parts of the
structure to the hazard of
being struck by the collapsing truss or structural collapse.
Note: Among other methods, one feasible and acceptable abatement method to
correct this hazard would be
following the hoisting requirements for roof trusses with a span greater
than 30 feet per the Truss
Manufacturer and/or Wood Truss Council of America's "Building Component
Safety Information" Bulletin
BCSI 1-03.
Recent events (2)
  • — I (S)
  • — Z (S)

1926.501 B01

Repeat Gravity 10 2 instances 3 exposed
Issued
Nov 7, 2005
Abate by
Nov 10, 2005
Penalty
Initial $10,000 · Current $7,500 Reduced
Recent events (2)
  • — I (R) $7500.00
  • — Z (R) $10000.00

1926.550 A09

Other-than-serious Gravity 01 1 instance 8 exposed
Issued
Nov 7, 2005
Abate by
Nov 10, 2005
Recent events (2)
  • — I (O)
  • — Z (O)

View PRO Builders's full OSHA safety record →