OSHA Inspection: GREEN MOUNTAIN STEEL ERECTORS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GREEN MOUNTAIN STEEL ERECTORS in NEW STUDENT CENTER, WILLIAMS COLLEGE, WILLIAMSTOWN, MA 01267 (NAICS 238190). OSHA activity number 308349281.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Green Mountain Steel Erectors — free Get an email when a new federal OSHA severe-injury report for Green Mountain Steel Erectors is published. One employer, no account, unsubscribe in one click.
Site address
NEW STUDENT CENTER, WILLIAMS COLLEGE
City
WILLIAMSTOWN
State
MA
ZIP
01267
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
SIC code (legacy)
1791
Employees
12
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 8, 2005
Abate by
Aug 11, 2005
Penalty
Initial $1,500 · Current $1,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment
and a place of employment which were free from recognized hazards that
were causing or likely to cause
death or serious physical harm to employees in that employees were exposed
to being struck by or crushed by
a 38,000 lb steel panel as the panel was being installed overhead using
improper rigging of synthetic slings:
Among other methods, two feasible and acceptable methods to correct this
hazard  include, but are not limited
to, (1) using slings specifically designed for use with materials having
sharp corners or (2), padding the slings
with material of sufficient strength to minimize damage to the sling as
referenced  in ANSI/ASME B30.9
(Slings), Section 9.4.9 (Operating Practices), paragraph (f).