MANGILAO, GU —
OSHA Inspection: SEONG JIN CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SEONG JIN CONSTRUCTION, INC. in U.O.G., MANGILAO, GU 96923 (NAICS 237110). OSHA activity number 308578921.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SEONG JIN CONSTRUCTION, INC.
- Site address
- U.O.G.
- City
- MANGILAO
- State
- GU
- ZIP
- 96923
- Mailing
- P.O. BOX 9296, TAMUNING, GU 96931
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- SIC code (legacy)
- 1629
- Employees
- 12
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 15, 2005
- Abate by
- Aug 2, 2005
- Penalty
- Initial $600 · Current $600
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a)University of Guam - Employees operated: 1. A Smiton excavator with a jack hammer attached, breaking lattle rocks in a trench. Nuts and bolts were used as coupling pins to hold jack hammer in-place. 2. A Catpillar backhoe, model-416 was used to move a compactor and dig around the project site. Metal rods were used as coupling pins to the front shovel and outrigger pads. 3. A Daewoo excavator, model-DH2000, 3/8 inch rebars were welded to hold shovel in-place. The excavator and backhoe had metal rods, rebars and nut and bolts, instead of the pins originally provided by the manufacturer, to secure the shovels, jack hammer and outrigger pads. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THE HAZARD IS: 1.To follow the Association of Equipment Manufacturers (AEM) "Safety Manual for Operating and Maintenance Personnel" which requires that damaged and missing parts are repaired or replaced, and 2.To follow the Manufacturer's Operator Manual by using only service parts meeting manufacturer specifications, and 3.To train operators and maintenance personnel to inspect equipment for defects and to complete service and repairs before equipment is placed back in service.
1926.602 A02 I
- Issued
- Jun 15, 2005
- Abate by
- Jun 30, 2005
More inspections at Seong JIN Construction, INC.
View Seong JIN Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308578921.