ELLENBORO, NC —
OSHA Inspection: THIEMAN METAL TECHNOLOGIES, L.L.C.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of THIEMAN METAL TECHNOLOGIES, L.L.C. in 531 WEBB ROAD, ELLENBORO, NC 28040 (NAICS 332999). OSHA activity number 309656684.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THIEMAN METAL TECHNOLOGIES, L.L.C.
- Site address
- 531 WEBB ROAD
- City
- ELLENBORO
- State
- NC
- ZIP
- 28040
- Mailing
- P.O. BOX 39, ELLENBORO, NC 28040
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- SIC code (legacy)
- 3499
- Employees
- 50
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
15 citations on file for this inspection.
95012901
- Issued
- Aug 4, 2006
- Abate by
- Aug 30, 2006
- Penalty
- Initial $100 · Current $100
General-duty citation text
North Carolina General Duty Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a) Facility, Laser Area - The crane system was not load tested prior to initial use. (b) Facility, Parts Washer - The crane system was not load tested prior to initial use. REF:ANSI B30.11-1998, Chapter 11-2, Paragraph 11-2.2.2 (a) New, reinstalled, altered, repaired and modified equipment should be load tested prior to initial use as determined by a qualified person. (b) If a load test is conducted, the load shall not be less than 100of the rated load of the equipment or more than 125of the rated load of the equipment, unless otherwise recommended by the manufacturer. (c) If a load test is conducted, the person conducting the load test shall prepare a written report of the load sustained during the test and the operations performed during the test. Reports shall be placed on file. NOTE: Among other methods, one feasible acceptable abatement method to correct this hazard is to conduct load testing of the crane system per the requirements of section 2.2.2 of ANSI B30-11-1998.
95012901
- Issued
- Aug 4, 2006
- Abate by
- Aug 30, 2006
- Penalty
- Initial $100 · Current $100
General-duty citation text
North Carolina General Duty Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a) Facilitywide - 12 Gorbel bridge crane systems with Coffing hoists were not inspected at frequent intervals (monthly). REF:ANSI B30.11-1998, Chapter 11-2.1.2 (a) Frequent inspections shall be performed at intervals defined in para. 11-2.1.1(b)(1) and shall include observations during operation. (c) A designated person shall determine whether conditions found during the inspection constitute a hazard and require a more detailed inspection. (d) The upper limit device on the hoist shall be checked, without a load on the hook, at the beginning of each work shift. Care shall be exercised. The load block shall be inched into its limit or run in at low speed. NOTE: Among other methods, one feasible acceptable abatement method to correct this hazard is to conduct frequent (monthly) inspections on the bridge crane system per the requirements of section 11-2.1.2 of ANSI B30.11-1998.
95012901
- Issued
- Aug 4, 2006
- Abate by
- Aug 30, 2006
- Penalty
- Initial $100 · Current $100
General-duty citation text
North Carolina General Duty Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a) Facilitywide - 12 Gorbel bridge crane systems with Coffing hoists were not inspected periodically (annually). REF:ANSI B30.11-1998, Chapter 11-2, Paragraph 11-2.1.3 (a) Periodic inspections shall be performed at intervals defined in para. 11-2.1.1(b)(2): Visual inspection by an appointed person making records of apparent external conditions to provide the basis for a continuing evaluation, as follows: normal service, equipment in place --- annually. (c) A qualified person shall examine any deficiencies found during the inspection to determine whether conditions found constitute a hazard, require disassembly for further inspection, or require replacement. NOTE: Among other methods, one feasible acceptable abatement method to correct this hazard is to conduct periodic (annual) inspections of the bridge crane system per the requirements of section 11-2.1.3 of ANSI B30.11-1998.
1910.179 H04
- Issued
- Aug 4, 2006
- Abate by
- Aug 30, 2006
- Penalty
- Initial $125 · Current $100 Reduced
Recent events (2)
- — I (S) $100.00
- — Z (S) $125.00
1910.184 E01
- Issued
- Aug 4, 2006
- Abate by
- Aug 30, 2006
- Penalty
- Initial $125 · Current $100 Reduced
Recent events (2)
- — I (S) $100.00
- — Z (S) $125.00
1910.184 E03 II
- Issued
- Aug 4, 2006
- Abate by
- Aug 30, 2006
1910.242 B
- Issued
- Aug 4, 2006
- Abate by
- Aug 30, 2006
- Penalty
- Initial $125
Recent events (2)
- — I (O)
- — Z (S) $125.00
1910.252 B02 III
- Issued
- Aug 4, 2006
- Abate by
- Sep 21, 2006
- Penalty
- Initial $100 · Current $100
1910.37 A03
- Issued
- Aug 4, 2006
- Abate by
- Aug 9, 2006
1910.106 E06 II
- Issued
- Aug 4, 2006
- Abate by
- Aug 9, 2006
1910.110 H12
- Issued
- Aug 4, 2006
- Abate by
- Aug 9, 2006
1910.134 D03 IIIB2
- Issued
- Aug 4, 2006
- Abate by
- Aug 30, 2006
1910.157 E03
- Issued
- Aug 4, 2006
- Abate by
- Aug 30, 2006
1910.303 G02 I
- Issued
- Aug 4, 2006
- Abate by
- Aug 9, 2006
1910.304 F04
- Issued
- Aug 4, 2006
- Abate by
- Aug 9, 2006
More inspections at Thieman Metal Technologies, L.L.C.
View Thieman Metal Technologies, L.L.C.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309656684.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.