BARTOW, FL —
OSHA Inspection: MOSAIC FERTILIZER, LLC
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of MOSAIC FERTILIZER, LLC in 4390 CR 640 W., BARTOW, FL 33830 (NAICS 325312). OSHA activity number 309674034.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOSAIC FERTILIZER, LLC
- Site address
- 4390 CR 640 W.
- City
- BARTOW
- State
- FL
- ZIP
- 33830
- Mailing
- P.O. BOX 2000, MULBERRY, FL 33860
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325312
- SIC code (legacy)
- 2874
- Employees
- 265
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jul 7, 2006
- Abate by
- Jul 13, 2006
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of falls: a)Sulfuric Acid Department - The loading area platform adjustable gangway/stair unit, which formed a guardrail equivalent when in the stored or "up" position, had an inoperative locking mechanism which failed to hold the stair unit in place, exposing employees to a fall of 11 feet, on or about 1/12/06. Among other methods, one feasible and acceptable method to correct this hazard is to follow the Carbis Inc. instruction manual for operation and maintenance under Maintenance item 1. Visually inspect the unit before each use. Replace any damaged parts. Monthly inspection of the unit is recommended as a minimum. Harsh atmosphere and/or heavy use may dictate more frequent inspections and lubication.
More inspections at Mosaic Fertilizer, LLC
View Mosaic Fertilizer, LLC's full OSHA safety record →
More inspections in this industry (NAICS 325312)
More inspections in FL
Source