Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOUTHWIND DRILLING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOUTHWIND DRILLING, INC. in WELL #1-33, SEC 33, TWP 27, MIDWAY, KS 67111 (NAICS 213111). OSHA activity number 309883437.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southwind Drilling, INC. — free Get an email when a new federal OSHA severe-injury report for Southwind Drilling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
WELL #1-33, SEC 33, TWP 27
City
MIDWAY
State
KS
ZIP
67111
Mailing
P.O. BOX 276, 8 N. MAIN ST., ELLINWOOD, KS 67526
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
SIC code (legacy)
1381
Employees
14
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 9 exposed
Issued
Apr 11, 2006
Abate by
Apr 14, 2006
Penalty
Initial $875 · Current $438 Reduced
Section 5(a)1 of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to struck by hazards:
Employees working the drilling rig #2 at Well #18, Section 18, Township 19
in Ness
County Kansas were exposed to struck by hazards created by the whipping
action of high
pressure hose in the event of a mud hose failure.  The 2 inch diamter mud
hoses that
discharged in the mud pits and the 4 inch diamter mud hose from the mud
house were
not protected by safety chains or cables.
Among other methods, one feasible and acceptable method to correct this
hazard is to secure the
hose ends using cables or chains properly located and of sufficient
strength to resist hose
whipping should it become disconnected or broken as referenced in
paragraph
9.13.4 of API RP
54, Recommended Practice for Occupational Safety for Oil and Gas Well
Drilling and Servicing
Operations, 1999 edition.
29 CFR 1903.19(c)(2) abatement of the above violation was verified at the
time of
inspection, no certification is required.
Recent events (2)
  • — I (S) $437.50
  • — Z (S) $875.00

1910.219 D01

Serious Gravity 02 1 instance 9 exposed
Issued
Apr 11, 2006
Abate by
Apr 14, 2006
Penalty
Initial $700 · Current $350 Reduced
Recent events (2)
  • — I (S) $350.00
  • — Z (S) $700.00

1910.219 E03 I

Serious Gravity 02 1 instance 9 exposed
Issued
Apr 11, 2006
Abate by
Apr 14, 2006

View Southwind Drilling, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309883437.