MIFFLINBURG, PA —
OSHA Inspection: RITZ-CRAFT CORP OF PENNSYLVANIA INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RITZ-CRAFT CORP OF PENNSYLVANIA INC in 15 INDUSTRIAL PARK, MIFFLINBURG, PA 17844 (NAICS 321992). OSHA activity number 310231337.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RITZ-CRAFT CORP OF PENNSYLVANIA INC
- Site address
- 15 INDUSTRIAL PARK
- City
- MIFFLINBURG
- State
- PA
- ZIP
- 17844
- Mailing
- P.O. BOX 70, MIFFLINBURG, PA 17844
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321992
- SIC code (legacy)
- 2452
- Employees
- 356
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 20, 2008
- Abate by
- May 6, 2008
- Penalty
- Initial $1,500 · Current $375 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm, including severe burns, to employees in that employees were exposed to dust explosion, deflagration, or other fire hazards from dust collectors being located inside a building. a) Plant #1 Dormer Shop: The Arrestall dust collector was located inside of the building and was not equipped with a deflagration suppression system or proper deflagration relief venting. The unit was not equipped with spark detection necessary to recycle exhaust air back into the facility, as observed on or about January 14, 2008. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE METHOD TO CORRECT THIS HAZARD IS TO RELOCATE THE DUST COLLECTOR OUTDOORS. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $375.00
- — Z (S) $1500.00
5(a)(1)
- Issued
- Mar 20, 2008
- Abate by
- May 6, 2008
- Penalty
- Initial $1,500 · Current $375 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to dust explosion, deflagration and other fire hazards: a) Plant #1 Dormer Shop: Plastic flex duct, being used to connect woodworking equipment to the dust collection systems, was not properly bonded and grounded, as observed on or about January 14, 2008. b) Plant #1 Dormer Shop: A length of nonconductive PVC pipe was used to connect a radial arm saw to the dust collection system, as observed on or about January 14, 2008. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE METHOD TO CORRECT THIS HAZARD IS TO EQUIP THE DUCT WORK WITH A BARE COPPER WIRE GROUNDED TO THE DUST COLLECTION SYSTEMS AND REPLACE THE LENGTH OF PVC PIPE WITH PROPER DUCT WORK. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $375.00
- — Z (S) $1500.00
1910.22 A01
- Issued
- Mar 20, 2008
- Abate by
- May 6, 2008
- Penalty
- Initial $1,500 · Current $375 Reduced
Recent events (2)
- — I (S) $375.00
- — Z (S) $1500.00
1910.307 B
- Issued
- Mar 20, 2008
- Abate by
- May 6, 2008
- Penalty
- Initial $1,125 · Current $375 Reduced
Recent events (2)
- — I (S) $375.00
- — Z (S) $1125.00
1910.305 B01 II
- Issued
- Mar 20, 2008
- Abate by
- May 6, 2008
More inspections at Ritz-Craft Corp of Pennsylvania INC
View Ritz-Craft Corp of Pennsylvania INC's full OSHA safety record →
More inspections in this industry (NAICS 321992)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310231337.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.