DACONO, CO —
OSHA Inspection: STEELSTAR CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STEELSTAR CORPORATION in 101 MILLER DR., DACONO, CO 80514 (NAICS 332114). OSHA activity number 310472360.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STEELSTAR CORPORATION
- Site address
- 101 MILLER DR.
- City
- DACONO
- State
- CO
- ZIP
- 80514
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332114
- SIC code (legacy)
- 3449
- Employees
- 94
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 28, 2008
- Abate by
- Apr 7, 2008
- Penalty
- Initial $700 · Current $490 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of exploding plastic compressed air lines: (a)Steelstar Corporation at 101 Miller Dr., Dacono, CO 80514: In the maintenance area of the facility, the employer was transporting above ground compressed air through schedule 80 polyvinyl chloride (PVC) pipes. The PVC pipe is used as part of a back-up compressed air system. This condition exposed the employees to the hazard of being struck by plastic shrapnel if the pipe explodes. Among other methods, two feasible and acceptable abatement methods to correct this hazard are to: (1)Follow American Society for Testing and Materials (ASTM) Standard D1785- 86, which states polyvinyl chloride (PVC), pipe can be used for transportation of compressed air and gases only if the PVC pipe is made of shatter resistant material or are encased in a shatter resistant material. (2)Replace all existing PVC pipes with a cast iron or other type of metal type piping rated to transport compressed air safety above ground. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Sample Abatement-Certification Letter").-Certification
Recent events (2)
- — I (S) $490.00
- — Z (S) $700.00
1910.134 D03 IIIB2
- Issued
- Mar 28, 2008
- Abate by
- Apr 7, 2008
- Penalty
- Initial $700 · Current $490 Reduced
Recent events (2)
- — I (O) $490.00
- — Z (S) $700.00
1910.147 C04 I
- Issued
- Mar 28, 2008
- Abate by
- Apr 7, 2008
- Penalty
- Initial $875 · Current $612 Reduced
Recent events (2)
- — I (O) $612.00
- — Z (S) $875.00
1910.212 A01
- Issued
- Mar 28, 2008
- Abate by
- Apr 7, 2008
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Steelstar Corporation
View Steelstar Corporation's full OSHA safety record →
More inspections in this industry (NAICS 332114)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310472360.