Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: STONEY CREEK TECHNOLOGIES

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of STONEY CREEK TECHNOLOGIES in 3300 W. 4TH STREET, TRAINER, PA 19061 (NAICS 325613). OSHA activity number 310716576.

Watch Stoney Creek Technologies — free Get an email when a new federal OSHA severe-injury report for Stoney Creek Technologies is published. One employer, no account, unsubscribe in one click.
Site address
3300 W. 4TH STREET
City
TRAINER
State
PA
ZIP
19061
Mailing
3300 WEST 4TH STREET, TRAINER, PA 19061
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325613
SIC code (legacy)
2843
Employees
15
Ownership type
A
Industry flags
Manufacturing safety.

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $375.00 · Current $144.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazards of incompatible chemicals in the flammable
storage area that could
create a potential for an intense or violent reaction, fire, exothermal
reaction, or release of toxic
gases.
a) Jobsite- 3330 West 4th Street, Trainer, PA.  Flammable storage area.
a) One gallon
(4 liters) of Muriatic acid (Hydrochloric acid) was stored on open
shelving along with
many gallons of incompatible chemicals such as 4 liters of Methylene
Chloride, 1 liter
of Chloroform, 4 Liters of Chlorobenzene, 5 gallons of Glycol Ether, 5
gallons of n-
butyl alcohol, 8 liters of Propionic acid. Accidental mixture of
Hydrochloric Acid and
one or more of the above mentioned chemicals could create a potential for
an
intense or
violent reaction ,or exothermal reaction, fire, or release of toxic gases.
Among other
methods, one feasible and acceptable abatement method to correct this
hazard is to
physically separate the hydrochloric acid from the flammable storage and
store it in a
cabinet with compatible chemicals. Observed on 6/1/2007
b) Jobsite-3330 West 4th Street, Trainer, PA.  Flammable storage area.
a) Eight liters
of Propionic Acid was stored on open shelving along with Xylene, Toluene,
Glycol
ether.  Accidental mixture of one or more ot the above mentioned chemicals
with
Propionic Acid may have the potential to cause a violent reaction or fire.
Among other
methods, one feasible and acceptable method to correct this hazard is to
physically
separate the Propionic acid from the flammable storage and store it in a
cabinet with
compatible chemicals.  Observed on 6/1/2007.
Recent events (2)
  • — I (S) $144.00
  • — Z (S) $375.00

1910.176 B

Serious Gravity 02 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $300.00 · Current $100.00 Reduced
Recent events (2)
  • — I (S) $100.00
  • — Z (S) $300.00

1910.1200 F05 I

Serious Gravity 02 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $300.00 · Current $100.00 Reduced
Recent events (2)
  • — I (S) $100.00
  • — Z (S) $300.00

1910.1200 F05 II

Serious Gravity 01 100 instances
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1910.22 A01

Serious Gravity 05 7 instances 2 exposed
Issued
Abate by
Penalty
Initial $1400.00 · Current $1200.00 Reduced
Recent events (2)
  • — I (S) $1200.00
  • — Z (S) $1400.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310716576.