SYRACUSE, NY ·
OSHA Inspection: M & W ALUMINUM PRODUCTS INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of M & W ALUMINUM PRODUCTS INC in 321 WAVEL STREET, SYRACUSE, NY 13206 (NAICS 332999). OSHA activity number 310752282.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M & W ALUMINUM PRODUCTS INC
- Site address
- 321 WAVEL STREET
- City
- SYRACUSE
- State
- NY
- ZIP
- 13206
- Mailing
- PO BOX 2672, SYRACUSE, NY 13220
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- SIC code (legacy)
- 3499
- Employees
- 14
- Ownership type
- Private (A)
- Industry flags
- Manufacturing safety.
Citations
14 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 7, 2007
- Abate by
- Jan 9, 2008
- Penalty
- Initial $750 · Current $488 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to THE HAZARD OF BEING STRUCK-BY: a)Receiving area, on or about 01/17/2002: Two Jet, 1 ton, overhead electric hoists, Serial Numbers unknown, had the safety latches removed and had no maintenance records to indicate annual or more frequent inspections. Among other methods, feasible and acceptable abatement methods to correct this hazard are to: 1.Conduct frequent and periodic inspections of all hoisting equipment and repair or replace broken, defective or missing components. 2.Maintain dated inspection reports or comparable records on critical items such as hoisting machinery and other lifting devices in accordance with ANSI B30.16-1993, Overhead Hoists, Chapter 16-1.2.9 Hooks and Chapter 16-2 Inspections and Maintenance. b)Receiving area, on or about 01/17/2002: Two overhead monorail beams holding 2-Jet, 1 ton, overhead electric hoists were never initially load tested, rated and marked and no frequent or periodic inspections have been conducted or maintained. Among other methods, feasible and acceptable abatement methods to correct this hazard are to: 1.Prior to initial use, all new, reinstalled, or modified equipment shall be tested to assure compliance with ANSI B30.11-1980, Monorail Systems. 2.Conduct frequent and periodic inspections of all hoisting equipment and repair or replace broken, defective or missing components. 2.Maintain dated inspection reports or comparable records on critical items such as hoisting machinery and other lifting devices in accordance with ANSI B30.11-1980, Monorail Systems, Chapter 11-2 through 11-2.1.5 and 11-2.3.3. Abatement certification must be submitted for these items.
Recent events (2)
- · I (S) $487.50
- · Z (S) $750.00
1910.36 D01
- Issued
- Dec 7, 2007
- Abate by
- Dec 12, 2007
- Penalty
- Initial $750 · Current $488 Reduced
Recent events (2)
- · I (S) $487.50
- · Z (S) $750.00
1910.37 B02
- Issued
- Dec 7, 2007
- Abate by
- Dec 12, 2007
Recent events (2)
- · I (S)
- · Z (S)
1910.37 B04
- Issued
- Dec 7, 2007
- Abate by
- Dec 12, 2007
Recent events (2)
- · I (S)
- · Z (S)
1910.37 B05
- Issued
- Dec 7, 2007
- Abate by
- Dec 12, 2007
Recent events (2)
- · I (S)
- · Z (S)
1910.124 G02
- Issued
- Dec 7, 2007
- Abate by
- Dec 20, 2007
- Penalty
- Initial $450 · Current $293 Reduced
Recent events (2)
- · I (S) $292.50
- · Z (S) $450.00
1910.178 P01
- Issued
- Dec 7, 2007
- Abate by
- Dec 12, 2007
- Penalty
- Initial $750 · Current $488 Reduced
Recent events (2)
- · I (S) $487.50
- · Z (S) $750.00
1910.212 A01
- Issued
- Dec 7, 2007
- Abate by
- Jan 9, 2008
- Penalty
- Initial $750 · Current $488 Reduced
Recent events (2)
- · I (S) $487.50
- · Z (S) $750.00
1910.215 A04
- Issued
- Dec 7, 2007
- Abate by
- Dec 12, 2007
Recent events (2)
- · I (S)
- · Z (S)
1910.215 B09
- Issued
- Dec 7, 2007
- Abate by
- Dec 12, 2007
Recent events (2)
- · I (S)
- · Z (S)
1910.304 G05
- Issued
- Dec 7, 2007
- Abate by
- Dec 12, 2007
- Penalty
- Initial $750 · Current $488 Reduced
Recent events (2)
- · I (S) $487.50
- · Z (S) $750.00
1910.305 B01 II
- Issued
- Dec 7, 2007
- Abate by
- Dec 12, 2007
Recent events (2)
- · I (S)
- · Z (S)
1910.305 G01 III
- Issued
- Dec 7, 2007
- Abate by
- Dec 12, 2007
Recent events (2)
- · I (S)
- · Z (S)
1910.147 C04 I
- Issued
- Dec 7, 2007
- Abate by
- Dec 12, 2007
Recent events (2)
- · I (O)
- · Z (O)
More inspections at M & W Aluminum Products INC
View M & W Aluminum Products INC's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 310752282.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.