SYRACUSE, NY ·
OSHA Inspection: M & W ALUMINUM PRODUCTS INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of M & W ALUMINUM PRODUCTS INC in 321 WAVEL STREET, SYRACUSE, NY 13206 (NAICS 336370). OSHA activity number 339611923.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M & W ALUMINUM PRODUCTS INC
- Site address
- 321 WAVEL STREET
- City
- SYRACUSE
- State
- NY
- ZIP
- 13206
- Mailing
- 321 WAVEL STREET, SYRACUSE, NY 13206
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336370
- Employees
- 14
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Jul 7, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Right-side Polishing Area, on or about 3/5/2014: A Dayton Industrial Motor with unguarded rotating chuck was used by employees to polish and buff metal rods. b) Left-side Polishing Area, on or about 3/5/2014: Le Blonde Lathe with unguarded rotating chuck was used by employees to polish and buff metal rods. c) Back-side Cutting Area, on or about 4/3/2014: Two Jet Milling Machines were not provided with a guard over the rotating chuck. d) Back-side Cutting Area, on or about 3/5/2014: Jet Band Saw with unused portion of the blade unguarded was used by employees for cutting metal. e) Front-side CNC Area, on or about 3/5/2014: Jet Drill Press with unguarded rotating chuck was used by employees to drill and tap parts. f) Front-side CNC Area, on or about 3/5/2014: Jet Lathe with unguarded rotating chuck was used by employees for tooling. g) Front-side CNC Area, on or about 4/3/2014: Shop Fox Drill Press with unguarded rotating chuck was used by employees for chamfer parts.
Recent events (2)
- · I (S) $1960
- · Z (S) $2800
1910.305 B01 II
- Issued
- Jul 7, 2014
- Abate by
- Jul 31, 2014
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Main Panel Area, on or about 3/5/2014: Metal Square D disconnect box used as main disconnect to a distribution panel had an unused opening not effectively closed on the lower right corner at the right side of the box. b) Main Panel Area, on or about 3/5/2014: Metal Distribution panel used as branch circuit distribution panel had an unused opening not effectively closed on the upper right corner at the right side of the box.
Recent events (2)
- · I (O) $0
- · Z (S) $1600
1910.305 G01 III
- Issued
- Jul 7, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iii): Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph: a) Front-side CNC Area, on or about 3/5/2014: A flexible extension cord was used as permanent wiring to power a Power Strip. b) Back-side CNC Area, on or about 3/5/2014: A flexible extension cord was used as permanent wiring to power a Hydraulic Press.
Recent events (2)
- · I (S) $0
- · Z (S) $1600
1910.157 E03
- Issued
- Jul 7, 2014
- Abate by
- Jul 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): The annual maintenance record (Fire Extinguisher) was not retained for one year after the last entry or the life of the shell, whichever is less: a) Back side of the Building, on or about 3/5/2014: Fire extinguisher maintenance record was not available upon request. b) Front side of the Building, on or about 3/5/2014: Fire extinguisher maintenance record was not available upon request.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 B02
- Issued
- Jul 7, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Front-side CNC Area, on or about 4/3/2014: An office rated power strip was used to provide power to drill press and an impulse sealer, exposing employees to minor burns.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at M & W Aluminum Products INC
View M & W Aluminum Products INC's full OSHA safety record →
More inspections in this industry (NAICS 336370)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339611923.