CALHOUN, GA —
OSHA Inspection: KERRY INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KERRY INC. in 221 SALEM ROAD SW, CALHOUN, GA 30701 (NAICS 311999). OSHA activity number 310961545.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KERRY INC.
- Site address
- 221 SALEM ROAD SW
- City
- CALHOUN
- State
- GA
- ZIP
- 30701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311999
- SIC code (legacy)
- 2099
- Employees
- 70
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 26, 2009
- Abate by
- May 27, 2009
- Penalty
- Initial $2,500
E200
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of an explosion, deflagration, or a fire because the combustible dust was not kept to a minimum by both capturing it at the point of generation and minimizing escape of fugitive combustible dust. Cleaning was performed in a manner which generated dust clouds: (a) Batter Package Line, Bagger area: The employer did not prevent the escape of dust from packaging equipment. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is to implement the requirement of NFPA 61 (2002) Sections 10.1 and 10.3.1.3 to enclose and, if necessary, vent or air aspirate the packaging to collect the dust normally emitted by rapid air displacement during filling. (b) Batter Package Line, bagger area: Compressed air was used to clean up combustible dust accumulation in the presence of ignition sources. Compressed air is used periodically with the packaging line running when there is an escape of dust at the bagging area. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is to periodically clean up dusts by using vacuum-cleaning devices designed for handling combustible dusts. Compressed air can only be used after all machinery in the area has been shut down and all sources of ignition controlled as specified by Section 10.2.2 of the National Fire Protection Association (NFPA) 61 "Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities," 2002 Edition. ABATEMENT DOCUMENTATION AND CERTIFICATION REQUIRED
Recent events (2)
- — J (S)
- — Z (S) $2500.00
5(a)(1)
- Issued
- Feb 26, 2009
- Abate by
- May 27, 2009
- Penalty
- Initial $2,500
E200
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of an explosion or a fire due to the ignition of a combustible dust by static discharge: (a) Batter Package Line, bagger area: Flexible duct hose and plastic (PVC) pipe were used at as part of the duct work to convey flour dust creating the potential for a combustible dust explosion inside the system. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is to comply with the National Fire Protection Association (NFPA) 61 "Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities," 2002 Edition. This includes ensuring that all duct work is electrically conductive and grounded and bonded per NFPA 61. ABATEMENT DOCUMENTATION AND CERTIFICATION REQUIRED
Recent events (2)
- — J (S)
- — Z (S) $2500.00
1910.303 B01 I
- Issued
- Feb 26, 2009
- Abate by
- Apr 14, 2009
- Penalty
- Initial $2,500 · Current $2,500
E200
Recent events (2)
- — J (S) $2500.00
- — Z (S) $2500.00
1910.1200 E01
- Issued
- Feb 26, 2009
- Abate by
- Apr 14, 2009
- Penalty
- Initial $1,500
Recent events (2)
- — J (S)
- — Z (S) $1500.00
1910.1200 F05 I
- Issued
- Feb 26, 2009
- Abate by
- Mar 10, 2009
- Penalty
- Current $2,000
0170
Recent events (2)
- — J (S) $2000.00
- — Z (S)
1910.1200 F05 II
- Issued
- Feb 26, 2009
- Abate by
- Mar 10, 2009
0170
Recent events (2)
- — J (S)
- — Z (S)
1910.146 F11
- Issued
- Feb 26, 2009
- Abate by
- Mar 24, 2009
Recent events (2)
- — J (O)
- — Z (O)
More inspections at Kerry INC.
View Kerry INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311999)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310961545.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.