LAS VEGAS, NV —
OSHA Inspection: FEATHER RIVER DOOR COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FEATHER RIVER DOOR COMPANY in 4390 FLOSSMOOR ST.# 400, LAS VEGAS, NV 89115 (NAICS 321911). OSHA activity number 311015374.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FEATHER RIVER DOOR COMPANY
- Site address
- 4390 FLOSSMOOR ST.# 400
- City
- LAS VEGAS
- State
- NV
- ZIP
- 89115
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321911
- SIC code (legacy)
- 2431
- Employees
- 45
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
29 citations on file for this inspection.
618037501
- Issued
- Jun 21, 2007
- Abate by
- Jul 4, 2007
- Penalty
- Initial $525 · Current $525
General-duty citation text
Nevada Revised Statute 618.375(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: The employer failed to ensure the Wulftec shrink wrapper machine was in good working conditions in accordance to manufacture's instructions, as follows: a.The four photoeyes to shut off the Wulftec shrink wrapper machine Model No. WRT200, Serial No. 13235-1-0204 were not working properly. An employee was observed walking by the photoeyes and the machine didn't stop. The employees were exposed to potential serious injuries. One feasible means of abatement is to follow the Manufacturer's Operating instructions and maintenance schedule.
1910.95 C01
- Issued
- Jun 21, 2007
- Abate by
- Jul 24, 2007
- Penalty
- Initial $525 · Current $525
1910.95 K01
- Issued
- Jun 21, 2007
- Abate by
- Jul 24, 2007
1910.110 F02 I
- Issued
- Jun 21, 2007
- Abate by
- Jul 4, 2007
- Penalty
- Initial $525 · Current $525
1910.213 C03
- Issued
- Jun 21, 2007
- Abate by
- Jul 9, 2007
- Penalty
- Initial $225 · Current $225
1910.215 B09
- Issued
- Jun 21, 2007
- Abate by
- Jun 29, 2007
- Penalty
- Initial $525 · Current $525
1910.305 A01 I
- Issued
- Jun 21, 2007
- Abate by
- Jun 29, 2007
- Penalty
- Initial $525 · Current $525
1910.305 G01 IIIA
- Issued
- Jun 21, 2007
- Abate by
- Jul 4, 2007
1910.305 G02 III
- Issued
- Jun 21, 2007
- Abate by
- Jul 4, 2007
618037601
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
618054202 A
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
618038301
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
1910.22 A03
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
1910.22 B02
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
1910.26 C02 IV
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
1910.37 A03
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
1910.37 B04
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
1910.37 B06
- Issued
- Jun 14, 2007
- Abate by
- Jun 19, 2007
1910.106 D07 III
- Issued
- Jun 14, 2007
- Abate by
- Jun 19, 2007
1910.132 D01
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
1910.134 C02 I
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
1910.157 C01
- Issued
- Jun 14, 2007
- Abate by
- Jun 19, 2007
1910.157 E03
- Issued
- Jun 14, 2007
- Abate by
- Jun 19, 2007
1910.169 B03 III
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
1910.169 B03 IV
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
1910.303 B01 I
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
1910.303 F
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
1910.304 F04
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
1910.1200 F09
- Issued
- Jun 14, 2007
- Abate by
- Jun 29, 2007
More inspections at Feather River Door Company
View Feather River Door Company's full OSHA safety record →
More inspections in this industry (NAICS 321911)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311015374.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.