RALEIGH, MS —
OSHA Inspection: PRIORITY ENERGY SERVICES, LLC
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of PRIORITY ENERGY SERVICES, LLC in COUNTY ROAD 99, SHELL OIL ROAD, RALEIGH, MS 39153 (NAICS 237120). OSHA activity number 311420830.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRIORITY ENERGY SERVICES, LLC
- Site address
- COUNTY ROAD 99, SHELL OIL ROAD
- City
- RALEIGH
- State
- MS
- ZIP
- 39153
- Mailing
- 22207 PRATS DAIRY RD, ABBITA SPRINGS, LA 70420
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237120
- SIC code (legacy)
- 1623
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 11, 2010
- Abate by
- Jan 14, 2010
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, employees were exposed to hazard of being struck by: (a) SONAT Metering Station - On or about July 15, 2009 employees were exposed to the hazard of being struck by high pressure gas, flying projectiles and other debris from the rupture of piping and pressure vessels during leak testing of gas metering stations that were pressurized with nitrogen gas. Employees performing pressure test were not protected from the hazards by the use of: hazards that were causing or likely to cause death or serious physical harm to employees, in that, employees were exposed to hazard of being struck by: (a) SONAT Metering Station - On or about July 15, 2009 employees were exposed to the hazard of being struck by high pressure gas, flying projectiles and other debris from the rupture of piping and pressure vessels during leak testing of gas metering stations that were pressurized with nitrogen gas. Employees performing pressure test were not protected from the hazards by the use of: a. Hydrostatic testing unless analysis demonstrate that hydrostatic testing is not feasible b. Remove employees from the area Among other methods, one feasible and acceptable abatement method to correct this hazard is to: Use hydrostatic (liquid) testing when feasible as specified in ASME B31.1- 2007, move non-essential employees to a safe distance as specified in the Midcontinent Express document entitled "Specifications for Nitrogen Pressure Testing" and provide physical barrier where feasible to protect employees from flying projectiles. Gradually increase pressure in steps until test pressure is reached.
1926.1052 C01
- Issued
- Jan 11, 2010
- Abate by
- Jan 14, 2010
- Penalty
- Initial $600
Recent events (2)
- — I (O)
- — Z (S) $600.00
More inspections at Priority Energy Services, LLC