TERRY, MS —
OSHA Inspection: PRIORITY ENERGY SERVICES, LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of PRIORITY ENERGY SERVICES, LLC in TETCO INTERCONNECT, 5354 MYER ROAD, TERRY, MS 39170 (NAICS 237120). OSHA activity number 313627424.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRIORITY ENERGY SERVICES, LLC
- Site address
- TETCO INTERCONNECT, 5354 MYER ROAD
- City
- TERRY
- State
- MS
- ZIP
- 39170
- Mailing
- 22207 PRATS DAIRY RD., ABITA SPRINGS, LA 70320
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237120
- SIC code (legacy)
- 1623
- Employees
- 4
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jan 11, 2010
- Abate by
- Jan 14, 2010
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, employees were exposed to hazard of being struck by: (a) TETCO Meter Station - On or about July 12, 2009 employees were exposed to the hazard of being struck by high pressure gas, flying projectiles and other debris from the rupture of piping and pressure vessels during leak testing of gas metering station that were pressurized with nitrogen gas. Employees performing these pneumatic pressure tests were not protected from the hazards by use of: a. Hydrostatic testing unless analysis demonstrate that hydrostatic testing is not feasible b. Remove employees from the area Among other methods, one feasible and acceptable abatement method to correct this hazard is to: Use hydrostatic testing when feasible as specified in ASME B31.1-2007, move non-essential employees to a safe distance as specified in Midcontinent Express document entitled "Specifications for Nitrogen Pressure Testing" and provide physical barrier where feasible to protect employees from flying projectiles. Gradually increase pressure in steps until test pressure is reached.
Recent events (2)
- — I (S) $3500.00
- — Z (S) $3500.00
More inspections at Priority Energy Services, LLC
View Priority Energy Services, LLC's full OSHA safety record →
More inspections in this industry (NAICS 237120)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313627424.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.