Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRIORITY ENERGY SERVICES, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of PRIORITY ENERGY SERVICES, LLC in TETCO INTERCONNECT, 5354 MYER ROAD, TERRY, MS 39170 (NAICS 237120). OSHA activity number 313627424.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Priority Energy Services, LLC — free Get an email when a new federal OSHA severe-injury report for Priority Energy Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
TETCO INTERCONNECT, 5354 MYER ROAD
City
TERRY
State
MS
ZIP
39170
Mailing
22207 PRATS DAIRY RD., ABITA SPRINGS, LA 70320
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237120
SIC code (legacy)
1623
Employees
4
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Jan 11, 2010
Abate by
Jan 14, 2010
Penalty
Initial $3,500 · Current $3,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees, in that, employees
were exposed to hazard of being struck by:
(a)  TETCO Meter Station - On or about July 12, 2009 employees were
exposed to the
hazard of being struck by high pressure gas, flying projectiles and other
debris from the
rupture of piping and pressure vessels during leak testing of gas metering
station that
were pressurized with nitrogen gas. Employees performing these pneumatic
pressure tests
were not protected from the hazards by use of:
a. Hydrostatic testing unless analysis demonstrate that hydrostatic
testing is not
feasible
b. Remove employees from the area
Among other methods, one feasible and acceptable abatement method to
correct this
hazard is to:  Use hydrostatic testing when feasible as specified in ASME
B31.1-2007,
move non-essential employees to a safe distance as specified in
Midcontinent Express
document entitled "Specifications for Nitrogen Pressure Testing" and
provide physical
barrier where feasible to protect employees from flying projectiles.
Gradually increase
pressure in steps until test pressure is reached.
Recent events (2)
  • — I (S) $3500.00
  • — Z (S) $3500.00

View Priority Energy Services, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313627424.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.