On , OSHA opened a referral safety inspection of GUTIERREZ CONSTRUCTION in LOT #47, BLOCK 1, KIMBERLY, ID 83341 (NAICS 238130). OSHA activity number 311582597.

Watch Gutierrez Construction — free Get an email when a new federal OSHA severe-injury report for Gutierrez Construction is published. One employer, no account, unsubscribe in one click.
Site address
LOT #47, BLOCK 1
City
KIMBERLY
State
ID
ZIP
83341
Mailing
537 UTAH STREET, GOODING, ID 83330
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
SIC code (legacy)
1751
Employees
6
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 4 instances 5 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $325.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and
a place of employment which were free from recognized hazards that were
causing or likely to cause death or
serious physical harm to employees in that employees were exposed to
structural collapse of the trusses and walls:
a)Southeast corner of structure at the garage; On or about 6/10/09 and at
times prior thereto, the
employer did not ensure that all top cord  temporary lateral restraints
(TCTLR) were installed as the
roof trusses were erected.
b)Southeast corner of structure at the garage; On or about 6/10/09 and at
times prior thereto, the
employer utilized strips of oriented strand board (OSB) in lieu of 2X4
stress graded lumber for top cord
temporary lateral restraints (TCTLR).
c)Southeast corner of structure at the garage; On or about 6/10/09 and at
times prior thereto, the
employer did not install top cord and/or web member diagonal bracing and
bottom cord temporary
lateral restraint (BCTLR) after erecting 5 trusses.
d)South center of structure at main entry area;  On or about 6/10/09 and
at times prior thereto, the
employer did not provide for initial exterior/interior ground bracing
before and after installing the first
two trusses.
Note 1: Abatement certification IS required for this item.
Note 2:  A feasible means of abatement would be to utilize/follow the WTCA
(Wood Truss Construction
Association)/TPI (Truss Plate Institute) BCSI (Building Component Safety
Information) publications, BCSI-B1:
Guide for Handling, Installing, Restraining & Bracing of Trusses; and BSCI
B-2: Truss Installation &
Temporary Restraint/Bracing for all wood truss erection./Bracing
Recent events (2)
  • — I (S) $325.00
  • — Z (S) $600.00

1926.501 B13

Serious Gravity 02 1 instance 5 exposed
Issued
Abate by

1926.1051 A

Serious Gravity 02 1 instance 5 exposed
Issued
Abate by

1926.95 A

Serious Gravity 01 4 instances 6 exposed
Issued
Abate by
Penalty
Initial $450.00 · Current $225.00 Reduced