PORT ALLEGANY, PA —
OSHA Inspection: SAINT GOBAIN CONTAINERS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SAINT GOBAIN CONTAINERS in ONE GLASS PLACE, PORT ALLEGANY, PA 16743 (NAICS 327213). OSHA activity number 311875728.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAINT GOBAIN CONTAINERS
- Site address
- ONE GLASS PLACE
- City
- PORT ALLEGANY
- State
- PA
- ZIP
- 16743
- Mailing
- ONE GLASS PLACE, PORT ALLEGHENY, PA 16743
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327213
- SIC code (legacy)
- 3221
- Employees
- 5000
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jun 18, 2010
- Abate by
- Jul 14, 2010
- Penalty
- Initial $2,625 · Current $1,585 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to unmarked natural gas shut-offs, improper natural gas connections, and natural gas hose connectors that were not suitable for the conditions of use: a) St. Gobain Container/Second Floor Area Near IS Machine--Master Heater --- (On or about Feburary 3, 2010: 1.) The Master natural gas fired heater was connected to the facility's natural gas piping system by hose connector that was not designed for regular movement, vibration, and potential physical damage. The hose connector was dented in at least one location. 2.) The end of the hose connector was slipped over the supply side fitting and was not attached by positive mechanical means. 3.) The manual gas shut-off that controlled the flow of natural gas from the facility's piping system to the Master natural gas fired heater was not labeled. ABATEMENT NOTE: Among other methods, feasible and acceptable methods to correct the conditions include: 1. Complying with the applicable requirements noted in NFPA 54/ANSI Z223.1 - National Fuel Gas Code 2. Complying with ANSI A10.10 Safety Requirements for Temporary and Portable Space Heating Devices 3. Conspicuously label the natural gas shut-off. 4. Acquire and install gas connectors that are rated, listed, and labeled for industrial environments, regular movement, and vibration. Flexible hoses made of various materials are commercially available. 5. Utilize fittings that positively and mechanically connect.
Recent events (2)
- — I (S) $1585.00
- — Z (S) $2625.00
More inspections at Saint Gobain Containers
View Saint Gobain Containers's full OSHA safety record →
More inspections in this industry (NAICS 327213)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311875728.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.