ROME, NY —
OSHA Inspection: EMPIRE AERO CENTER
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EMPIRE AERO CENTER in 394 HANGAR ROAD, ROME, NY 13441 (NAICS 488190). OSHA activity number 312369614.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EMPIRE AERO CENTER
- Site address
- 394 HANGAR ROAD
- City
- ROME
- State
- NY
- ZIP
- 13441
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488190
- SIC code (legacy)
- 4581
- Employees
- 350
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 15, 2009
- Abate by
- Aug 3, 2009
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to THE HAZARD OF BEING STRUCK-BY: Should the hoist fail allowing the load to fall and strike and employee. a)At the facility, on or about 06/24/09: Three underhung overhead hoists were being operated without having received a periodic inspection in more than twelve months. Among other methods, one feasible and acceptable abatement method to correct this hazard is to: Ensure all underhung overhead hoists receive frequent and periodic inspections as required by the manufacturer and the American Society of Mechanical Engineers (ASME B30.16-1993) document, paragraph 16- 2.1.1(b)(2) which states; visual inspection by a designated person who makes records of external conditions to provide the basis for continuing evaluation. An external coded mark on the hoist is an acceptable identification in lieu of records. (a) normal service - yearly. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1400.00
- — Z (S) $2000.00
1910.147 C04 IIB
- Issued
- Jul 15, 2009
- Abate by
- Aug 17, 2009
- Penalty
- Initial $1,500 · Current $1,050 Reduced
Recent events (2)
- — I (S) $1050.00
- — Z (S) $1500.00
1904.2 A
- Issued
- Jul 15, 2009
- Abate by
- Sep 28, 2009
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Empire Aero Center
View Empire Aero Center's full OSHA safety record →
More inspections in this industry (NAICS 488190)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312369614.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.