Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: STOCK BUILDING SUPPLY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STOCK BUILDING SUPPLY in 50 WEST STOEVER AVENUE, MYERSTOWN, PA 17067 (NAICS 444110). OSHA activity number 312500804.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stock Building Supply for free Get an email when a new federal OSHA severe-injury report for Stock Building Supply is published. One employer, no account, unsubscribe in one click.
Site address
50 WEST STOEVER AVENUE
City
MYERSTOWN
State
PA
ZIP
17067
Mailing
P.O. BOX 437, MYERSTOWN, PA 17067
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444110
SIC code (legacy)
5211
Employees
25
Ownership type
Private (A)
Industry flags
Manufacturing safety.

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 1 exposed
Issued
Apr 16, 2009
Abate by
May 12, 2009
Penalty
Initial $900 · Current $900
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment
and a place of employment which were free from recognized hazards that
were causing or likely to cause
death or serious physical harm to employees in that employees were exposed
to severe burn injuries from the
potential dust explosion that could have resulted from, or have been
exacerbated by, the location of the
enclosureless portion of the dust collector in the adjacent room, lack of
a backflash damper on the exhaust
ductwork and the lack of deflagration vents for the cyclone collector:
(a)The dust collection system and the ductwork used to collect the wood
dust was not protected
by a deflagration vents for the enclosureless portion of the ventilation
system and a back flash
damper in the event of a fire or explosion, on or about January 14, 2009.
(b)The cyclone did not have any deflagration vents to realease excessive
pressure in the event of a
wood dust explosion, on or about January 14, 2009.
AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO
CORRECT THESE HAZARDS INCLUDES FOLLOWING NFPA 664, STANDARD FOR
PREVENTION OF FIRES AND EXPLOSIONS IN WOOD PROCESSING AND WOODWORKING
FACILITIES, 2007 EDITION, INCLUDING BUT NOT LIMITED TO: INSTALL A BACK
FLASH
DAMPER ON THE EXHAUST DUCTWORK. PROVIDE DEFLAGRATION VENTING FOR
ENCLOSURELESS PORTION ROOM. PROVIDE DEFLAGRATION VENTS FOR CYCLONE
PORTION OF DUST COLLECTION SECTION TO RELASE PRESSURE IN THE EVENT OF A
DUST EXPLOSION.
VERIFICATION REQUIRED

1910.213 C02

Serious Gravity 02 2 instances 2 exposed
Issued
Apr 16, 2009
Abate by
May 12, 2009
Penalty
Initial $900 · Current $900

1910.213 C03

Serious Gravity 02 1 instance 2 exposed
Issued
Apr 16, 2009
Abate by
May 12, 2009

1910.22 A01

Other-than-serious Gravity 01 2 instances 2 exposed
Issued
Apr 16, 2009
Abate by
May 12, 2009

View Stock Building Supply's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 312500804.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.