MYERSTOWN, PA ·
OSHA Inspection: STOCK BUILDING SUPPLY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STOCK BUILDING SUPPLY in 50 WEST STOEVER AVENUE, MYERSTOWN, PA 17067 (NAICS 444110). OSHA activity number 312500804.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STOCK BUILDING SUPPLY
- Site address
- 50 WEST STOEVER AVENUE
- City
- MYERSTOWN
- State
- PA
- ZIP
- 17067
- Mailing
- P.O. BOX 437, MYERSTOWN, PA 17067
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444110
- SIC code (legacy)
- 5211
- Employees
- 25
- Ownership type
- Private (A)
- Industry flags
- Manufacturing safety.
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 16, 2009
- Abate by
- May 12, 2009
- Penalty
- Initial $900 · Current $900
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to severe burn injuries from the potential dust explosion that could have resulted from, or have been exacerbated by, the location of the enclosureless portion of the dust collector in the adjacent room, lack of a backflash damper on the exhaust ductwork and the lack of deflagration vents for the cyclone collector: (a)The dust collection system and the ductwork used to collect the wood dust was not protected by a deflagration vents for the enclosureless portion of the ventilation system and a back flash damper in the event of a fire or explosion, on or about January 14, 2009. (b)The cyclone did not have any deflagration vents to realease excessive pressure in the event of a wood dust explosion, on or about January 14, 2009. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THESE HAZARDS INCLUDES FOLLOWING NFPA 664, STANDARD FOR PREVENTION OF FIRES AND EXPLOSIONS IN WOOD PROCESSING AND WOODWORKING FACILITIES, 2007 EDITION, INCLUDING BUT NOT LIMITED TO: INSTALL A BACK FLASH DAMPER ON THE EXHAUST DUCTWORK. PROVIDE DEFLAGRATION VENTING FOR ENCLOSURELESS PORTION ROOM. PROVIDE DEFLAGRATION VENTS FOR CYCLONE PORTION OF DUST COLLECTION SECTION TO RELASE PRESSURE IN THE EVENT OF A DUST EXPLOSION. VERIFICATION REQUIRED
1910.213 C02
- Issued
- Apr 16, 2009
- Abate by
- May 12, 2009
- Penalty
- Initial $900 · Current $900
1910.213 C03
- Issued
- Apr 16, 2009
- Abate by
- May 12, 2009
1910.22 A01
- Issued
- Apr 16, 2009
- Abate by
- May 12, 2009
More inspections at Stock Building Supply
View Stock Building Supply's full OSHA safety record →
More inspections in this industry (NAICS 444110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 312500804.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.