ALSIP, IL —
OSHA Inspection: COCA COLA ENTERPRISES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COCA COLA ENTERPRISES in 12200 S. LARAMIE AVE., ALSIP, IL 60803 (NAICS 424820). OSHA activity number 312595366.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COCA COLA ENTERPRISES
- Site address
- 12200 S. LARAMIE AVE.
- City
- ALSIP
- State
- IL
- ZIP
- 60803
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424820
- SIC code (legacy)
- 5182
- Employees
- 144
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Oct 26, 2009
- Abate by
- Mar 12, 2010
- Penalty
- Initial $1,875 · Current $1,875
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employement and a place of employment that were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to inhalation hazards associated with anhydrous ammonia. Machinery room: On or about May 08, 2009, employees were not adequately protected against the potential release of anhydrous ammonia in that: a. A door communicating with the building's syrup area opened into and not out of the machinery room. b. Audible and visual ammonia alarms were not provided on the outside of doors communicating with the machinery room, specifically the three doors on the NE side of the machinery room, also the door between the machinery room and the syrup area, with reset to be located inside the machinery room. c. A schematic drawing or panel giving directions for the operation of the refrigeration system was not provided at a location convenient for the operators of the equipment. d. Entrances to the refrigerating machinery room were not provided with permanent legible and securely attached signs reading "Machinery Room--Authorized Personnel Only", specifically the three doors on the NE side of the machinery room, and further communicating that entry is forbidden except by those personnel trained in emergency procedures when the ammonia alarm has been activated, specifically all of the five doors communicating with the machinery room. e. Emergency shutdown procedures, including precautions to be observed in case of a breakdown or leak, were not posted outside of the machinery room, immediately adjacent to each door. Among other methods, feasible and acceptable methods to control these hazards are to adhere to the safe design, installation and operation of anhydrous ammonia refrigeration systems as prescribed by ANSI/ASHRAE 15-2007, "Safety Standard for Refrigeration Systems", specifically: a. Reconfigure the door communicating with the syrup area to open out of the machinery room. (Section 8.11.2) b. Provide audible and visible ammonia alarms outside of each machinery room door with reset inside the machinery room. (Section 8.11.2.1) c. Provide a schematic drawing or panel giving directions for the operation of the refrigeration system in a location convenient for the operators. (Section 11.7) d. Provide legible permanent signs, securely attached and easily accessible, reading "Machinery Room--Authorized Personnel Only" on the three doors on the NE side of the machinery room, and further communicating that entry is forbidden except by personnel traine in emergencyprocedures when the ammonia larm has been activated on all five machinery room doors. (Section 11.2.4) e. Post emergency procedures outside the machinery room immediately adjacent to each door. (Section 11.7)
Recent events (2)
- — I (O) $1875.00
- — Z (S) $1875.00
More inspections at Coca Cola Enterprises
View Coca Cola Enterprises's full OSHA safety record →
More inspections in this industry (NAICS 424820)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312595366.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.