OSHA Inspection: SULZER TURBO SERVICE

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SULZER TURBO SERVICE in 5740 WIEL RD, MARION, TX 78244 (NAICS 333611). OSHA activity number 312853898.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sulzer Turbo Service for free Get an email when a new federal OSHA severe-injury report for Sulzer Turbo Service is published. One employer, no account, unsubscribe in one click.
Site address
5740 WIEL RD
City
MARION
State
TX
ZIP
78244
Mailing
11518 OLD LA PORTE ROAD, LA PORTE, TX 77571
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333611
SIC code (legacy)
3511
Employees
35
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 2 exposed
Issued
Jan 25, 2010
Abate by
Dec 1, 2010
Penalty
Initial $1,750 · Current $1,100 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to a struck by hazard:
On or about 11/18/09, at the PSEG site, employees were working on a
turbine generator.
This generator had a ongoing static pressure test in progress.  The
employees of Sulzer was
unaware of the test in progress and remove a access door.  This door was
pressurize and blew
off, injuring two employees.
Among other methods, one feasible and acceptable abatement method to
correct this
hazard is to inform all employees working near or on the generator of the
ongoing test.  The
employer failed to inform the employees of the test, any hazards
associated with the test and
precautions that needed to be taken during the test.g
Recent events (2)
  • · F (S) $1100.00
  • · Z (S) $1750.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312853898.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.