WAYNE, NJ ·
OSHA Inspection: SAINT-GOBAIN PERFORMANCE PLASTICS
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of SAINT-GOBAIN PERFORMANCE PLASTICS in 150 DEY ROAD, WAYNE, NJ 07470 (NAICS 326121). OSHA activity number 312863145.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAINT-GOBAIN PERFORMANCE PLASTICS
- Site address
- 150 DEY ROAD
- City
- WAYNE
- State
- NJ
- ZIP
- 07470
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326121
- SIC code (legacy)
- 3082
- Employees
- 188
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jun 25, 2010
- Abate by
- Jul 28, 2010
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of suffering pulmonary edema as a result of exposure to hazardous vapors produced by the thermal decomposition of Polytetrafluoroethylene: a)Zitex Oven Room: Polytetrafluoroethylene(PTFE) used to manufacture filters for jet engines underwent thermal decomposition exposing employees to hazardous vapors such as, but not limited to, Carbonyl fluoride, Carbon Monoxide, Hydrogen Fluoride, and Perfluoroisobutylene, due to a failure of a thremocouple allowing the oven temperature to reach 1000 degrees Fahrenheit which was well above the PTFE decomposition temperature of 752 degrees Fahrenheit, on or about 1/7/10. Among other methods, feasible and acceptable means of abatement to correct this hazard would be to: 1) Ensure that PTFE temperature does not exceed 752 degrees Fahrenheit; 2)Install an audible alarm and a visual warning light to warn employees in case of thermocouple malfunction; and 3)Install an additional thermocouple as a back-up to further prevent a run away temperature rise.
Recent events (2)
- · I (S) $3150.00
- · Z (S) $4500.00
More inspections at Saint-Gobain Performance Plastics
View Saint-Gobain Performance Plastics's full OSHA safety record →
More inspections in this industry (NAICS 326121)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 312863145.