LA MARQUE, TX —
OSHA Inspection: GULF GREYHOUND PARK
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GULF GREYHOUND PARK in 1000 FM 2004, LA MARQUE, TX 77568 (NAICS 713290). OSHA activity number 312925316.
Where did this inspection happen?
- Establishment
- GULF GREYHOUND PARK
- Site address
- 1000 FM 2004
- City
- LA MARQUE
- State
- TX
- ZIP
- 77568
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713290
- SIC code (legacy)
- 9999
- Employees
- 215
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 18, 2011
- Abate by
- Apr 8, 2011
- Penalty
- Initial $6,300 · Current $5,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer does not furnish employment and a place of employment which is free from recognized hazards that cause or are likely to cause death or serious physical harm to employees in that employees are exposed to: the hazards of falls while performing maintenance activities and repairs while working on an UpRight mobile scaffold, at the Gulf Greyhound Race Track in La Marque, TX, on or about the date of November 19, 2010, when an employee ascended on to the third tier of the scaffold which tipped and fell. Among other methods, recognized and feasible means of abatement to correct the hazard is to comply with the: Manufacturer's UpRight Instruction Manual, Span Scaffolds: 1)Scaffolds shall be erected, moved and dismantled only by, or under the supervision and direction of, a competent person. 2)Always make sure all locking hooks are firmly in position an latches are properly engaged. Never force locking hooks. 3)Always use four OUTRIGGERS if platform height will exceed three (3) times any minimum base dimension (see Figure 4, page 3). American National Standards Institute (ANSI)/American Society of Safety Engineers (ASSE) Standard A10.8-2001, General Requirements for all scaffolds: 1)Paragraph 4.1, Scaffolds shall be furnished, erected, and used in accordance with this standard na available manufacturer specifications for persons engaged in work that cannot be done safely from the ground or from a permanent structure. 2)Paragraph 4.43, All employees using scaffolds to perform a job task shall be instructed by a qualified person in the proper construction, use, placement, care, and recognition of hazards for the scaffolds they are using. 3)Section 11, Manually Propelled and Prefabricated Mobile Scaffolds, Paragraph 11.3.3.4, Scaffolds shall be erected, used, and disassembled in accordance with the instructions furnished by the manufacturer.
Recent events (2)
- — I (S) $5000.00
- — Z (S) $6300.00
1910.26 C02 IV
- Issued
- Feb 18, 2011
- Abate by
- Mar 3, 2011
- Penalty
- Initial $2,700 · Current $2,000 Reduced
Recent events (2)
- — I (O) $2000.00
- — Z (S) $2700.00
1910.28 A02
- Issued
- Feb 18, 2011
- Abate by
- Mar 3, 2011
- Penalty
- Initial $3,600
Recent events (2)
- — I (S)
- — Z (S) $3600.00
1904.29 B02
- Issued
- Feb 18, 2011
- Abate by
- Mar 3, 2011
- Penalty
- Initial $1,000 · Current $1,000
Recent events (2)
- — I (O) $1000.00
- — Z (O) $1000.00
1904.40 A
- Issued
- Feb 18, 2011
- Abate by
- Mar 3, 2011
Recent events (2)
- — I (O)
- — Z (O)
More inspections in this industry (NAICS 713290)