Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: STURGEON ELECTRIC COMPANY, INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of STURGEON ELECTRIC COMPANY, INC. in 5005 W. 120TH AVE., BROOMFIELD, CO 80020 (NAICS 237130). OSHA activity number 313415499.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sturgeon Electric Company, INC. for free Get an email when a new federal OSHA severe-injury report for Sturgeon Electric Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5005 W. 120TH AVE.
City
BROOMFIELD
State
CO
ZIP
80020
Mailing
12150 EAST 112TH AVENUE, HENDERSON, CO 80640
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (Y)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
SIC code (legacy)
1629
Employees
6
Ownership type
Private (A)

4 citations on file for this inspection.

1926.453 B02 VI

Deleted Serious Gravity 10 3 instances 8 exposed
Issued
Jul 14, 2010
Abate by
Aug 3, 2010
Penalty
Initial $6,300 · Current $6,300
Recent events (2)
  • · I (S) $6300.00
  • · Z (S) $6300.00

1926.502 D16 III

Deleted Serious Gravity 10 3 instances 8 exposed
Issued
Jul 14, 2010
Abate by
Aug 3, 2010
Penalty
Initial $6,300 · Current $6,300
Recent events (2)
  • · I (S) $6300.00
  • · Z (S) $6300.00

5(a)(1)

Serious Gravity 10 3 instances 8 exposed
Issued
Jul 14, 2010
Abate by
Sep 15, 2010
Penalty
Initial $6,300 · Current $6,300
29 CFR 1926.453(b)(2)(vi):  Boom and basket load limits specified by the
manufacturer were
exceeded:
(a)Sturgeon Electric Company, Inc. at 5005 W. 120th Ave., Broomfield, CO
80020:
On or before January 15, 2010, the exposing employer exceeded the bucket
load
limits of the Terex Telelect Hi-Ranger 5FC-55 articulating aerial device
in two
instances:
1)The manufacturer specified load limit for the bucket and boom was 550
pounds. The weight of the two men in the elevated bucket, the bucket liner,
and tools, equaled 579 pounds. In addition, the boom was used to raise and
lower two All Aluminum Conductor (AAC) 795 conductors, which weighed a
minimum of 154 pounds each. When combined with the weight of the
employees, bucket liner and tools, the total weight exceeded the bucket and
boom load limit of 550 pounds by at least 183 pounds or 33 percent. While
employees were in the process of removing deenergized conductors, the upper
boom collapsed.
2)Earlier in the morning, two different crew members used the bucket to
raise
and lower the AAC 795 conductors.  The weight of the two men in the
elevated bucket, the bucket liner, and tools, equaled 482 pounds.  Each
conductor was estimated to weigh a minimum of 154 pounds.  The total
weight exceeded the bucket load limit of 550 pounds by at least 86 pounds,
or
15 percent.
Note: The overloading of the bucket off-center also created a bucket
tipping hazard,
with the potential for ejection of the occupants.
Abatement Note:  Abatement certification and documentation are required
for this
item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
  • · I (S) $6300.00
  • · Z (S) $6300.00

5(a)(1)

Serious Gravity 10 3 instances 8 exposed
Issued
Jul 14, 2010
Abate by
Oct 31, 2010
Penalty
Initial $6,300 · Current $6,300
29 CFR 1926.502(d)(16)(iii):  Personal fall arrest systems, when stopping
a fall, were not
rigged such that employees could neither free fall more than 6 feet, nor
contact any lower
level:
(a)Sturgeon Electric Company, Inc. at 5005 W. 120th Ave., Broomfield, CO
80020:
Recent events (2)
  • · I (S) $6300.00
  • · Z (S) $6300.00

View Sturgeon Electric Company, INC.'s full OSHA safety record →