EL PASO, TX —
OSHA Inspection: BRANDENBURG
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of BRANDENBURG in 2301 W. PAISANO DR., EL PASO, TX 79922 (NAICS 331512). OSHA activity number 313500225.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRANDENBURG
- Site address
- 2301 W. PAISANO DR.
- City
- EL PASO
- State
- TX
- ZIP
- 79922
- Mailing
- 2625 SOUTH LOOMIS ST., CHICAGO, IL 60608
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331512
- SIC code (legacy)
- 3324
- Employees
- 12
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jul 1, 2011
- Abate by
- Jul 13, 2011
- Penalty
- Initial $5,000 · Current $4,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the conditions listed below: On or about 02/26/2011, and times prior to, in the RCC evaporator, employees were cutting into a metal vesel to retrieve Titanium that was inside. Employees were trained in fire fighting but were given a water extinguisher in case of a metal fire. This condition exposed employees to severe burn hazards due to the water reacting with the fire. NFPA 48413.3.3.5 states: The following agents shall no be used as extinguishing agents on a combustible-metal fires because of adverse conditons or ineffectiveness: 1. Water 2. Foams 3. Halon etc A feasible abatement: Employer to provide proper fire fighting equipment in the event of a metal fire. Proper fire fighting equipment should be but not limited to, class D fire extinguisher.
Recent events (2)
- — F (S) $4000.00
- — Z (S) $5000.00
More inspections at Brandenburg
View Brandenburg's full OSHA safety record →
More inspections in this industry (NAICS 331512)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313500225.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.