Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: STAR CONSTRUCTION LLC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of STAR CONSTRUCTION LLC. in PATTON CHAPEL ROAD & CRAYRICH DR., HOOVER, AL 35244 (NAICS 237130). OSHA activity number 313766578.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Star Construction LLC. for free Get an email when a new federal OSHA severe-injury report for Star Construction LLC. is published. One employer, no account, unsubscribe in one click.
Site address
PATTON CHAPEL ROAD & CRAYRICH DR.
City
HOOVER
State
AL
ZIP
35244
Mailing
100 ANDERSON AVE., ANNISTON, AL 36201
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
SIC code (legacy)
1623
Employees
4
Ownership type
Private (A)

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 30, 2009
Abate by
Nov 4, 2009
Penalty
Initial $5,000 · Current $3,300 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to hazards associate with entering a confined space:
a.  On or about 9/23/09 - Patton Chapel Road & Crayrick Drive, Hoover, AL,
employee(s) entered a manhole without forced air ventilation and did not
perform air
monitoring to test the space for contaminants.
Among other methods, one feasible and acceptable method to correct this
hazard is to
enforce the use of a confined space program as specified in ANSI
Z117.1-1995,
American National Safety Institute Requirements for Confined Spaces.d