WAUSEON, OH —
OSHA Inspection: MULTI-CAST CORPORATION
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of MULTI-CAST CORPORATION in 225 E. LINFOOT STREET, WAUSEON, OH 43567 (NAICS 331524). OSHA activity number 313786873.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MULTI-CAST CORPORATION
- Site address
- 225 E. LINFOOT STREET
- City
- WAUSEON
- State
- OH
- ZIP
- 43567
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331524
- SIC code (legacy)
- 3365
- Employees
- 44
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- May 17, 2011
- Abate by
- Jun 16, 2011
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that natural gas fired burners on the melting furnace located in the melt department of the foundry were not equipped with combustion safeguards that shut off the fuel gas if the burner flame is extinguished: a.Multi-Cast Corporation located in Wauseon, Ohio: On or about February 11, 2011, the employees operated furnaces such as but not limited to furnace #1 located in the melt department, without combustion safe guards that shut off the fuel gas. There were no devices to monitor gas pressure, air pressure, the presence of a pilot flame or burner flame or a required timed purge cycle. Among other methods, one feasible and acceptable method to correct this hazard is to equip the furnace with combustion safeguards according to NFPA 86 "Standard for Ovens and Furnaces"- 2011 edition. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation ( using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — F (S) $3500.00
- — Z (S) $3500.00
1910.184 C09
- Issued
- May 17, 2011
- Abate by
- May 20, 2011
- Penalty
- Initial $4,900 · Current $1,000 Reduced
Recent events (2)
- — F (S) $1000.00
- — Z (S) $4900.00
1910.1025 L01 I
- Issued
- May 17, 2011
- Abate by
- Jun 2, 2011
- Penalty
- Initial $3,500 · Current $1,000 Reduced
1591
Recent events (2)
- — F (S) $1000.00
- — Z (S) $3500.00
More inspections at Multi-Cast Corporation
View Multi-Cast Corporation's full OSHA safety record →
More inspections in this industry (NAICS 331524)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313786873.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.