Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PEP BOYS #0190

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of PEP BOYS #0190 in 216 HIGHLAND AVENUE, SEEKONK, MA 02771 (NAICS 811111). OSHA activity number 313803637.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PEP Boys #0190 — free Get an email when a new federal OSHA severe-injury report for PEP Boys #0190 is published. One employer, no account, unsubscribe in one click.
Establishment
PEP BOYS #0190
Site address
216 HIGHLAND AVENUE
City
SEEKONK
State
MA
ZIP
02771
Mailing
3111 W. ALLEGHENY AVENUE, PHILADELPHIA, PA 19132
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
SIC code (legacy)
7538
Employees
25
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Repeat Gravity 10 1 instance 2 exposed
Issued
Dec 15, 2010
Abate by
Jan 31, 2011
Penalty
Initial $38,500 · Current $19,250 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees, in that, employees
were exposed to the hazards of being struck by strut springs being
released while under pressure
in the Branick Strut Spring Compressor:
Employees were exposed to struck by hazards from the Branick Spring
Compressor due to worn
or missing hooks and rubber hook pads that contain the compressed spring.
Four hooks were
visibly worn, one rubber hook pad was missing and the remaining five
rubber hook pads were
visibly worn.
A feasible and useful method to correct this hazard, among other methods:
1. Institute a
preventive maintenance program according to the manufacturer's
specifications.
2. Provide
training to employees on the hazards of operating the Strut Spring
compressor and the methods
to control or eliminate those hazards including but not limited to
following instructions in the
compressor operator's manual.  3. Schedule and complete periodic annual
inspections.
PEP BOYS #0190 WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS
OCCUPATIONAL SAFETY AND HEALTH STANDARD WHICH WAS CONTAINED IN
OSHA INSPECTION NUMBER 310677513, CITATION NUMBER 1, ITEM 1, ISSUED ON
MARCH 21, 2008, WITH A FINAL ORDER DATE OF OCTOBER 30, 2008, AND A FINAL
ABATEMENT DATE OF MAY 7, 2008.
Recent events (2)
  • — I (R) $19250.00
  • — Z (R) $38500.00

View PEP Boys #0190's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313803637.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.