HAZLETON, PA —
OSHA Inspection: BEMIS COMPANY INCORPORATED
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BEMIS COMPANY INCORPORATED in 20 JAYCEE DRIVE, HAZLETON, PA 18202 (NAICS 326199). OSHA activity number 314163254.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BEMIS COMPANY INCORPORATED
- Site address
- 20 JAYCEE DRIVE
- City
- HAZLETON
- State
- PA
- ZIP
- 18202
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- SIC code (legacy)
- 3089
- Employees
- 500
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Aug 10, 2011
- Abate by
- Sep 26, 2011
- Penalty
- Initial $3,750
General-duty citation text
Section 5 (a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to dust explosion, deflagration or other hazards from a dust collection system used to collect low density polyethylene (PPA) dust (class II Dust) which was located inside the building: a) The enclosureless dust collection system located inside the Extrusion Department contained twenty four bulk storage containers with a combined internal volume of approximately 200 cubic feet. This exceeds the 8 cubic feet limit established by the National Fire Protection Association (NFPA) 654 "Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, Handing of Combustible Particulate Solids, 2006 Edition. b) The dust collection system was not equipped with a deflagration suppression system. c) The dust collection system was not equipped with deflagration vents that are vented through ducts to the outside. d) Recycled air from the air-material separator exhaust did not achieve a filter efficiency of 99.9 percent at 10 microns as required by NFPA 654 Section 6.1.3. Observed on or about May 13, 2011. ABATEMENT CERTIFICATION REQUIRED ABATEMENT NOTE: Among other methods, a feasible abatement method to correct this hazard includes: Relocate the dust collector system outside the building or modify the system so that it fully complies with the National Fire Protection Association (NFPA) 654 "Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handing of Combustible Particulate Solids." 2006 Edition.
Recent events (2)
- — F (S)
- — Z (S) $3750.00
More inspections at Bemis Company Incorporated
View Bemis Company Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314163254.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.