Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BEMIS COMPANY INCORPORATED

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BEMIS COMPANY INCORPORATED in 20 JAYCEE DRIVE, HAZLETON, PA 18202 (NAICS 326199). OSHA activity number 335476180.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bemis Company Incorporated — free Get an email when a new federal OSHA severe-injury report for Bemis Company Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
20 JAYCEE DRIVE
City
HAZLETON
State
PA
ZIP
18202
Mailing
20 JAYCEE DRIVE, HAZLETON, PA 18202
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
487
Ownership type
A

5 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 11, 2012
Abate by
Dec 28, 2012
Penalty
Initial $3,300 · Current $2,475 Reduced
29 CFR 1910.23(c)(1):     Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:    a) Production Area Press #21 - Employees used a 6' 6" high platform to service the machine but the guardrails on the machine was not continuous, thereby exposing the employees to a fall hazard, observed on or about 7-16-12.    Abatement cetification required.
Recent events (2)
  • — I (S) $2475
  • — Z (S) $3300

1910.23 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 11, 2012
Abate by
Dec 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.23(a)(2):     Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person can not walk directly into the opening:    a) Production Area Press #6 - Employees used a 6'8" platform to service the machine but the opening used to access the work platform from the ladder did not have a standard railing or other acceptable means to guard the opening, thereby exposing the employees to a fall hazard, observed on or about 7-16-12.    Abatement certification required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.27 B01 III

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 11, 2012
Abate by
Jan 8, 2013
Penalty
Initial $4,125 · Current $3,094 Reduced
29 CFR 1910.27(b)(1)(iii):     The minimum clear length of rungs or cleats was not 16 inches.    a) Ladder Accessing the Resin Silos From the Production Area Roof - Employees used a ladder on resin silo #4 to access the top of the 22 foot high resin silos and that ladder had rungs that were only 12 1/4 inches in length thereby exposing the employees to a fall hazard, observed on or about 7-16-12.    Abatement Certification Required
Recent events (2)
  • — I (S) $3093.75
  • — Z (S) $4125

1910.23 A09

Other-than-serious 1 instance 1 exposed
Issued
Dec 11, 2012
Abate by
Jan 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.23(a)(9):     Every floor hole into which persons cannot accidentally walk (on account of fixed machinery, equipment or walls) was not protected by a cover that leaves no openings more than 1 inch wide.  The cover shall be securly held in palce to prevent tools or materials from falling through:    a) Extruder Machine #2 - Employees walked past this end of this machine where a 9 foot by 12 1/2 inch opening under the edge of the machine did not have a cover, observed on or about 7-16-12.    Abatement certification required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 II

Other-than-serious 1 instance 1 exposed
Issued
Dec 11, 2012
Abate by
Jan 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii):     The employer did not certify that periodic inspections of the energy control procedures had been performed:    (a) Production Area - The employees use Lock Out Tag Out procedures when working on equipment throughout the facility but the periodic inspections of those procedures being used on machines such as exruders and printers were not certified as of the time of the inpsection, reported on or about 7-16-12.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Bemis Company Incorporated's full OSHA safety record →